Predator 69672 Скачать руководство пользователя страница 6

      Page 6

For Generator technical questions, please call 1-888-866-5797.

For Engine technical questions, please call 1-800-520-0882.

Item  69672  69674        

SAFETY

OPERA

TION

MAINTENANCE

SETUP

 Functional Description

Specifications

Generator

Output

120/240VAC, 60Hz

5,500 Running Watts (6,500 Peak Watts)

Electrical Receptacle

Two 3‑Prong, duplex NEMA #5‑20 120V

One 4‑Prong, NEMA #L14‑30 twistlock 120V/240V 

One DC Outlet 12VDC

Engine

Displacement

420cc

Engine Type

Horizontal Single Cylinder 4 stroke OHV 

EPA phase III compliant

Cooling System

Forced air cooled

Fuel

Type

87+ octane unleaded gasoline

Capacity

6.1 Gallons (23L)

Engine Oil

Type SAE

10W‑30 above 32° F

 5W‑30 at 32° F or below

Capacity

1.16 Quart (1.1L)

Run Time @ 50% load

12 hr.

Operational Volume

74 dB

Available accessories

Wheel kit (sold separately)

 Item  69674

 ‑ The emission control system for this Generator’s Engine is warranted for standards set by the U.S. 

Environmental Protection Agency and by the California Air Resources Board (also known as CARB).  For warranty 

information, refer to the last pages of this manual. 

Item 69672

 ‑ The emission control system for this Generator’s Engine is warranted for standards set by the U.S. 

Environmental Protection Agency.  For warranty information, refer to the last pages of this manual.

Components and Controls

 

Fuel Cap

Frame

Starter 

Handle

DC Circuit Breaker

Fuel Valve

Power Switch

AC Circuit Breakers

Choke

Low Oil Indicator

AC Receptacles

Air Filter

DC Receptacle

Ground Terminal

Содержание 69672

Страница 1: ......

Страница 2: ...wed including the following Set up Precautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable ma...

Страница 3: ...ially while it is operating 6 Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spil...

Страница 4: ...ded conductive objects such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doin...

Страница 5: ...speed 6 Wear ANSI approved safety goggles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadab...

Страница 6: ...t 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit sold separately Item 69674 The emission control system for this Generator s Eng...

Страница 7: ...ent only to the Receptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit...

Страница 8: ...enerator Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do so To ground the Generator connect a 6 AWG ground...

Страница 9: ...nd or causing damage 4 Then replace the Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs i...

Страница 10: ...gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do...

Страница 11: ...rge batteries without a proper charge controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads...

Страница 12: ...atts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use...

Страница 13: ...P Stopping the Engine in an Emergency 1 To stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the...

Страница 14: ...a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment...

Страница 15: ...ine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt the crankcase slightly to help dr...

Страница 16: ...ally enter the engine and cause rust damage Apply a thin coat of rust preventive oil to all metal parts 2 FUEL WARNING TO PREVENT SERIOUS INJURY FROM FIRE Drain the fuel tank in a well ventilated area...

Страница 17: ...oke to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1...

Страница 18: ...ine to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fue...

Страница 19: ...r Carburetor 1 55 Packing Insulator 1 56 Carburetor Assy 1 57 Packing Air Cleaner 1 58 Nut Flange 2 59 Air Cleaner Assy 1 60 Element Air Cleaner Assy 1 61 Clip Harness 1 62 Grommet Cord 1 63 Holder St...

Страница 20: ...ipe Clip 2 109 Bolt Flange M6 25 4 110 Washer 6 25 2 4 111 Collar Tank Cushion 4 112 Rubber Fuel Cushion 4 113 Rubber Fuel Tank Mounting 2 114 Pipe 1 115 Pipe 1 116 Carbon 1 117 Bracket Carbon 1 118 G...

Страница 21: ...Page 21 For Generator technical questions please call 1 888 866 5797 For Engine technical questions please call 1 800 520 0882 Item 69672 69674 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram...

Страница 22: ...tions please call 1 888 866 5797 For Engine technical questions please call 1 800 520 0882 Item 69672 69674 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram cont Note Parts 114 117 and 141 143 are...

Страница 23: ...ol system on your engine for the periods of time described below provided there has been no abuse neglect or improper maintenance of your engine Your emission control system may include parts such as...

Страница 24: ...rts which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommenda...

Отзывы: