For Generator technical questions, please call 1-888-866-5797.

For Engine technical questions, please call 1-800-520-0882.

Item  69672  69674        

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Table of Contents

Safety ......................................................... 2
Setup .......................................................... 6
Specifications ............................................. 6
Operation .................................................... 8

Maintenance .............................................. 14
Parts List and Diagram .............................. 19
Warranty .................................................... 23

WARNING SYMBOLS AND DEFINITIONS

This is the safety alert symbol.  It is used to alert you to potential personal injury hazards.  

Obey all safety messages that follow this symbol to avoid possible injury or death.

Indicates a hazardous situation which, if not avoided,  

will result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in minor or moderate injury.

Addresses practices not related to personal injury.

IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO PERSONS

WARNING

 – When using tools, basic precautions should always be followed, including the following:

Set up Precautions

1.  Gasoline fuel and fumes are flammable, and 

potentially explosive.  Use proper fuel storage 

and handling procedures.  Do not store fuel 

or other flammable materials nearby.

2.  Have multiple ABC class fire extinguishers nearby.

3.  Operation of this equipment may create sparks 

that can start fires around dry vegetation. A spark 

arrestor may be required. The operator should 

contact local fire agencies for laws or regulations 

relating to fire prevention requirements.

4.  Set up and use only on a flat, level, 

well‑ventilated surface.

5.  All connections and conduits from the Generator 

to the load must only be installed by trained and 

licensed electricians, and in compliance with all 

relevant local, state, and federal electrical codes and 

standards, and other regulations where applicable.

6.  Connections for standby power to a building 

electrical system must be made by a qualified 

electrician. The connection must isolate the 

generator power from utility power, and must comply 

with all applicable laws and electrical codes. 

7.  Wear ANSI‑approved safety goggles, heavy‑duty 

work gloves, and dust mask/respirator during set up.

8.  Use only lubricants and fuel 

recommended in this manual.

Содержание 69672

Страница 1: ......

Страница 2: ...wed including the following Set up Precautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable ma...

Страница 3: ...ially while it is operating 6 Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spil...

Страница 4: ...ded conductive objects such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doin...

Страница 5: ...speed 6 Wear ANSI approved safety goggles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadab...

Страница 6: ...t 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit sold separately Item 69674 The emission control system for this Generator s Eng...

Страница 7: ...ent only to the Receptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit...

Страница 8: ...enerator Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do so To ground the Generator connect a 6 AWG ground...

Страница 9: ...nd or causing damage 4 Then replace the Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs i...

Страница 10: ...gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do...

Страница 11: ...rge batteries without a proper charge controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads...

Страница 12: ...atts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use...

Страница 13: ...P Stopping the Engine in an Emergency 1 To stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the...

Страница 14: ...a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment...

Страница 15: ...ine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt the crankcase slightly to help dr...

Страница 16: ...ally enter the engine and cause rust damage Apply a thin coat of rust preventive oil to all metal parts 2 FUEL WARNING TO PREVENT SERIOUS INJURY FROM FIRE Drain the fuel tank in a well ventilated area...

Страница 17: ...oke to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1...

Страница 18: ...ine to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fue...

Страница 19: ...r Carburetor 1 55 Packing Insulator 1 56 Carburetor Assy 1 57 Packing Air Cleaner 1 58 Nut Flange 2 59 Air Cleaner Assy 1 60 Element Air Cleaner Assy 1 61 Clip Harness 1 62 Grommet Cord 1 63 Holder St...

Страница 20: ...ipe Clip 2 109 Bolt Flange M6 25 4 110 Washer 6 25 2 4 111 Collar Tank Cushion 4 112 Rubber Fuel Cushion 4 113 Rubber Fuel Tank Mounting 2 114 Pipe 1 115 Pipe 1 116 Carbon 1 117 Bracket Carbon 1 118 G...

Страница 21: ...Page 21 For Generator technical questions please call 1 888 866 5797 For Engine technical questions please call 1 800 520 0882 Item 69672 69674 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram...

Страница 22: ...tions please call 1 888 866 5797 For Engine technical questions please call 1 800 520 0882 Item 69672 69674 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram cont Note Parts 114 117 and 141 143 are...

Страница 23: ...ol system on your engine for the periods of time described below provided there has been no abuse neglect or improper maintenance of your engine Your emission control system may include parts such as...

Страница 24: ...rts which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommenda...

Отзывы: