Components and Controls (continued)

The following are descriptions of the controls 
on the power panel.  Your Generator has 
sockets to power your products with circuit 
breakers to protect the voltage flow. 

1. 

I

O

START

Engine Switch:  

Used to start and stop the Engine.  

  

2. 

AC Receptacles:  

The Generator contains several 

AC Receptacles to power tools and equipment.   

a. 

RESET

TEST

RESET

TEST

3-prong, duplex  
120 volt GFCI receptacle  
(NEMA #5-20) 

b. 

3-prong, twistlock,  
120 volt receptacle 
(NEMA #L5-20) 

c. 

4-prong, twistlock,  
120/240 volt receptacle 
(NEMA #L14-30)

WARNING!  

Connect tools and equipment 

only to the Receptacle (120 volt or 240 volt) 
that is compatible with the electrical 
characteristics and rated capacities of 
the tools and equipment being used.  

3. 

ON
OFF

Circuit Breakers: 

The circuit breaker protects 

the Generator from overloading.  The rating of the 
breaker and the load it protects are marked near 
the breaker.  Should any of the Circuit Breakers trip, 
the Generator will stop the electricity output.  If this 
happens, unplug all loads from the Generator.   
Allow the Generator to cool down.  Then, press 
the tripped Circuit Breaker, restart the Engine, and 
re-attach loads. 

4. 

12 VDC Receptacle: 

12 VDC Receptacle provides 

a power source for 12 volt DC items.  

5. 

Grounding Terminal:  

Prior to each use, set 

up the ground wire (not included) connection to 
the Grounding Terminal to properly ground the 
Generator.  Refer to 

Grounding

 on page 8 

for instructions on grounding the Generator.

Содержание 63086

Страница 1: ...manual and the receipt in a safe and dry place for future reference 18l Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or...

Страница 2: ...instructed of the reasons for the restrictions applied to the location and about any precautions that must be taken Access shall be through the use of a special tool or lock and key or other means of...

Страница 3: ...perating 6 Keep all spectators at least six feet from the Engine during operation 7 Do not touch engine during use Let engine cool down after use 8 Never store fuel or other flammable materials near t...

Страница 4: ...r piece of equipment 28 Do not operate in explosive atmospheres such as in the presence of flammable liquids gases or dust Gasoline powered engines may ignite the dust or fumes 29 Keep grounded conduc...

Страница 5: ...rrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit...

Страница 6: ...l Type 87 octane stabilizer treated unleaded gasoline Capacity 6 6 Gallons 25L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Spark Plug Type NHSP Torch F6TC Gap...

Страница 7: ...only to the Receptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit brea...

Страница 8: ...V 9Ah battery not included in the battery holder on the Generator 2 Bolt in place using the hardware included with the Generator 3 Attach the positive red cable connector from the engine to the Positi...

Страница 9: ...the engine 2 Close the fuel valve 3 Place a bowl under the fuel cup to catch any spilled fuel CAUTION Carburetor bowl may have gas in it which will leak upon removing the bolt 4 Unthread the bolt hold...

Страница 10: ...e full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use The...

Страница 11: ...If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5...

Страница 12: ...ve minutes with no load after each start up so that the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several...

Страница 13: ...ppliances tools and equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive appliances tools and equipment should be the last to be...

Страница 14: ...age Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an...

Страница 15: ...gine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off th...

Страница 16: ...r engine have a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or...

Страница 17: ...n plug 4 Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the ar...

Страница 18: ...an using water The water will gradually enter the Engine and cause rust damage Apply a thin coat of rust preventive oil to all metal parts 2 FUEL To protect the fuel tank during storage fill the tank...

Страница 19: ...and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to CHOKE position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connected securel...

Страница 20: ...blems 1 Fill fuel tank with fresh 87 octane stabilizer treated unleaded gasoline Do not use gasoline with more than 10 ethanol E15 E20 E85 etc 2 Do not exceed equipment s load rating 3 Have qualified...

Страница 21: ...IAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO...

Страница 22: ...79 Impeller 1 80 Flywheel Sub 1 81 Bolt 2 82 Coil Ignition 1 83 Bolt 1 84 Clamp Charge Coil 1 85 Bolt 2 86 Coil Sub Charge 1 87 Bolt 2 88 Control Assembly Throttle 1 89 Spring Throttle Valve Returning...

Страница 23: ...Page 23 For technical questions please call 1 888 866 5797 ITEM 63086 SAFETY SETUp OpERATION MAINTENANCE Assembly Diagram...

Страница 24: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLI...

Страница 25: ...components of the emissions control system and are covered by this two 2 year warranty For a full list of emissions control components covered by this warranty please see 40 CFR 1068 Appendix I 1 Fue...

Страница 26: ...Page 26 For technical questions please call 1 888 866 5797 ITEM 63086 SAFETY SETUp OpERATION MAINTENANCE...

Страница 27: ...Page 27 For technical questions please call 1 888 866 5797 ITEM 63086 SAFETY SETUp OpERATION MAINTENANCE...

Страница 28: ...3491 Mission Oaks Blvd pO Box 6009 Camarillo CA 93011 1 888 866 5797...

Отзывы: