Predator 63086 Скачать руководство пользователя страница 3

Page 3

For technical questions, please call 1-888-866-5797.

ITEM 63086 
        

S

AFETY

S

ETU

p

Op

ERA

TION

M

AINTENANCE

Set up precautions (continued)

8.  Wear ANSI-approved safety goggles, heavy-duty 

work gloves, and dust mask/respirator during set up.

9.  Use only lubricants and fuel 

recommended in this manual.

10.  Improper connections to a building electrical system 

can allow electrical current from the Generator 
to backfeed into the utility lines.  Such backfeed 
may electrocute utility company workers or others 

who contact the lines during a power outage, and 
the Generator may explode, burn, or cause fires 
when utility power is restored.  Consult the utility 
company and a qualified electrician if intending 
to use the Generator for back up power.

11.  Do not operate the Generator before grounding.  

The Generator must be earth-grounded 
in accordance with all relevant electrical 
codes and standards before operation.

Operating precautions

1. 

CARBON MONOXIDE HAZARD 
Using a generator indoors CAN KILL 
YOU IN MINUTES. 

Generator exhaust contains carbon 
monoxide.  This is a poison you cannot 
see or smell. 

NEVER use inside a home or garage, EVEN IF 
doors and windows are open. 

Only use OUTSIDE and far away from windows, 
doors, and vents.

2.  Never use a generator indoors, including in 

garages, basements, crawlspaces and sheds.  
Opening doors and windows or using fans will NOT 
prevent carbon monoxide build up in the home.

3.  When using generators, keep them outdoors 

and far away from open doors, windows, 
and vents to avoid toxic levels of carbon 
monoxide from building up indoors.

4.  If you start to feel sick, dizzy, or weak while 

using a generator, get to fresh air right away.  
The carbon monoxide from generators can 
quickly lead to full incapacitation and death.

5.  Keep children away from the equipment, 

especially while it is operating. 

6.  Keep all spectators at least six feet 

from the Engine during operation.

7.  Do not touch engine during use.  

Let engine cool down after use. 

8.  Never store fuel or other flammable 

materials near the engine.

9.  Fire Hazard! Do not fill gas tank while engine is 

running.  Do not operate if gasoline has been spilled.  
Clean spilled gasoline before starting engine. 
Do not operate near pilot light or open flame.

10.  If the plugged in product operates abnormally 

or unusually slow, immediately stop using the 
Generator as a power source.  Always read and 
adhere to the instruction manual of the product 
to be powered, to make sure that it can be safely 
and efficiently powered by a portable generator.  

11.  Before connecting an appliance or power cord 

to the Generator:  Make sure that it is in good 
working order.  Faulty appliances or power cords 
can create a potential for electrical shock.

12.  Do not exceed the maximum power rating of the 

Generator.  Make sure that the total electrical rating 
of the all of the tools or appliances plugged into 
the Generator at the same time does not exceed 
that of the Generator.  Check that the startup 
surge will not be beyond the limit of the Generator.  
Power levels between rated and maximum 
may be used for no more than 30 minutes.

13.  Avoid substantially overloading which will 

trip the circuit breaker.  Exceeding the time 
limit for maximum power operation or slightly 
overloading the Generator may not switch the 
circuit breaker or circuit protector OFF, but will 
shorten the service life of the Generator.

14.  Do not attempt to connect or disconnect 

load connections while standing in 
water, or on wet or soggy ground.

15.  Do not touch electrically energized parts of 

the Generator and interconnecting cables 
or conductors with any part of the body, or 
with any non-insulated conductive object.

16.  Connect the Generator only to a load or 

electrical system (120 volt or 240 volt) that is 
compatible with the electrical characteristics 
and rated capacities of the Generator.

Содержание 63086

Страница 1: ...manual and the receipt in a safe and dry place for future reference 18l Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or...

Страница 2: ...instructed of the reasons for the restrictions applied to the location and about any precautions that must be taken Access shall be through the use of a special tool or lock and key or other means of...

Страница 3: ...perating 6 Keep all spectators at least six feet from the Engine during operation 7 Do not touch engine during use Let engine cool down after use 8 Never store fuel or other flammable materials near t...

Страница 4: ...r piece of equipment 28 Do not operate in explosive atmospheres such as in the presence of flammable liquids gases or dust Gasoline powered engines may ignite the dust or fumes 29 Keep grounded conduc...

Страница 5: ...rrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit...

Страница 6: ...l Type 87 octane stabilizer treated unleaded gasoline Capacity 6 6 Gallons 25L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Spark Plug Type NHSP Torch F6TC Gap...

Страница 7: ...only to the Receptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit brea...

Страница 8: ...V 9Ah battery not included in the battery holder on the Generator 2 Bolt in place using the hardware included with the Generator 3 Attach the positive red cable connector from the engine to the Positi...

Страница 9: ...the engine 2 Close the fuel valve 3 Place a bowl under the fuel cup to catch any spilled fuel CAUTION Carburetor bowl may have gas in it which will leak upon removing the bolt 4 Unthread the bolt hold...

Страница 10: ...e full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use The...

Страница 11: ...If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5...

Страница 12: ...ve minutes with no load after each start up so that the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several...

Страница 13: ...ppliances tools and equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive appliances tools and equipment should be the last to be...

Страница 14: ...age Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an...

Страница 15: ...gine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off th...

Страница 16: ...r engine have a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or...

Страница 17: ...n plug 4 Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the ar...

Страница 18: ...an using water The water will gradually enter the Engine and cause rust damage Apply a thin coat of rust preventive oil to all metal parts 2 FUEL To protect the fuel tank during storage fill the tank...

Страница 19: ...and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to CHOKE position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connected securel...

Страница 20: ...blems 1 Fill fuel tank with fresh 87 octane stabilizer treated unleaded gasoline Do not use gasoline with more than 10 ethanol E15 E20 E85 etc 2 Do not exceed equipment s load rating 3 Have qualified...

Страница 21: ...IAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO...

Страница 22: ...79 Impeller 1 80 Flywheel Sub 1 81 Bolt 2 82 Coil Ignition 1 83 Bolt 1 84 Clamp Charge Coil 1 85 Bolt 2 86 Coil Sub Charge 1 87 Bolt 2 88 Control Assembly Throttle 1 89 Spring Throttle Valve Returning...

Страница 23: ...Page 23 For technical questions please call 1 888 866 5797 ITEM 63086 SAFETY SETUp OpERATION MAINTENANCE Assembly Diagram...

Страница 24: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLI...

Страница 25: ...components of the emissions control system and are covered by this two 2 year warranty For a full list of emissions control components covered by this warranty please see 40 CFR 1068 Appendix I 1 Fue...

Страница 26: ...Page 26 For technical questions please call 1 888 866 5797 ITEM 63086 SAFETY SETUp OpERATION MAINTENANCE...

Страница 27: ...Page 27 For technical questions please call 1 888 866 5797 ITEM 63086 SAFETY SETUp OpERATION MAINTENANCE...

Страница 28: ...3491 Mission Oaks Blvd pO Box 6009 Camarillo CA 93011 1 888 866 5797...