© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 62
The lift capacitor is mounted inside the lift motor. If the lift capacitor is shorted, the lift fuse will
blow. The capacitor may be checked by disconnecting the lift motor connector from the Motor
Controller and using an ohmmeter to measure between pins 5 & 6 of the lift motor connector. If
the lift capacitor is leaky, it may work for lighter people and not for others, while if it is open it will
not work at all. If the capacitor is open or leaky it cannot be determined with an ohmmeter so
the following test will determine if the capacitor is bad.
4. With the incline below 15% (to allow room for lift travel), connect an AC voltmeter between
terminals 5 (black) & 6 (red) of the INCLINE connector. See Figures 4 and 5 for reference.
Set the treadmill in the manual program and press the INCLINE
key. The AC voltmeter
should read between 1.5 to 2.0 times the AC line voltage. If this reading is significantly low,
replace the lift motor. Note that the AC line voltage reading will only be present before an
error condition is displayed.
o
If the capacitor is bad the lift motor must be replaced.
5. The lift switch could fail in an operated (shorted) condition. If this happens the lift will move
(either up or down) as soon as the unit is powered up. The typical result is that the lift will be
physically jammed as described above, and it will also probably cause the internal lift fuse to
blow. If the lift moves un-commanded as soon as the power is turned on to the machine and
eventually jams, the Motor Controller must be replaced. The lift switch may also fail in an
open condition. If this happens the lift will not operate in one direction. Perform the following
steps to determine if the switch is open.
6. With the incline below 15% (to allow room for lift travel up), connect an AC voltmeter
between terminals 1 (white) & 6 (red) of the INCLINE connector. (See Figures 4 and 5 for
connector location and pin numbering). Set the treadmill in the manual program and press
the INCLINE
key. The AC voltmeter should read AC line voltage (either 120VAC or
240VAC). Note that the AC line voltage reading will only be present before an error condition
is displayed. A correct reading here verifies that the UP switch is working properly.
7. With the incline above 0% (to allow room for lift travel down), connect an AC voltmeter
between terminals 1 (white) & 5 (black) of the INCLINE connector. Set the treadmill in the
manual program and press the INCLINE
key. The AC voltmeter should read AC line
voltage (either 120VAC or 240VAC). Note that the AC line voltage reading will only be
present before an error condition is displayed. A correct reading here verifies that the DOWN
switch is working properly.
o
If either of these conditions fail, the Motor Controller must be replaced
.
If a lift motor winding is bad, the lift will not operate in one or both directions depending
on the exact fault in the motor. Replace the lift motor if the previous tests all pass.
Error 42 - Lift Position Value Out of Range
MCL
– Green
ASL
– Yellow Solid
Содержание TRM 811.v2
Страница 1: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 1 Service Manual...
Страница 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 93...
Страница 104: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 104 Exploded View...
Страница 105: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Страница 106: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 106...
Страница 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 107...
Страница 108: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 108...
Страница 109: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 109...
Страница 110: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 110...