© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 32
-
Blue Pulsing
– The following conditions will cause the ASL to pulse blue:
1.
Belt Rating 0 or 1
A belt rating of 0 or 1 will cause a blue pulsing ASL light indicating that there is a problem
with the running belt/deck and is in need of servicing or replacement.
2.
Belt Maintenance Reminder
A blue pulsing ASL light is also used as a 1000 mile running belt cleaning PM task
reminder. The mileage counter resets to 1000 and counts down to 0 miles triggering the
ASL light indicating that
it’s time for belt cleaning maintenance.
How to reset a blue pulsing ASL light
P10/P30 consoles:
a Access the Information Display (
6,5
).
b PM Belt Maintenance Reminder ASL reset: Select
Maintenance Test > Treadmill
Maintenance
> press and hold
QUIKSTART
until
1000 Miles
is displayed.
c Belt/Deck replacement ASL reset: select
Maintenance Test > Belt Rating >
press
and hold
QUICKSTART
to reset.
P80/P82 consoles:
a Access the service diagnostic page (
5,1,7,6,5,7,6,1
).
b
Select the
Maintenance
page.
c PM Belt Maintenance Reminder ASL reset: s
elect
Next Maintenance Due
>
Reset
.
d Belt/Deck replacement ASL reset:
select
Belt Rating
>
REPLACE
to reset.
Yellow Pulsing
– There are two states for yellow pulsing:
o
An error has recently occurred or is occurring. This state is temporary, as the MC
will attempt to resolve the issue and clear the codes so the tread can continue
working if possible. This alleviates the tread being out of order until a technician is
available to reset the MC.
o
If the MC cannot reset the error a fatal error has occurred and service is required.
The
treadmill is not operational.
Service is required to correct the fault. After the
fault is corrected, the ASL is reset to solid Blue by cycling power to the treadmill, or
through the Active Status Light submenu in the Hardware Validation menu, or by
clearing the error log.
-
Yellow Solid
– The treadmill has identified an irregular electronic/electrical occurrence
however it was not a fatal error and the MC was able to reset
–
treadmill is operational
.
This occurrence has created an error code and is available in the error log so the servicer
can determine if further service is needed. The ASL is reset to Blue solid by cycling power
to the treadmill, or through the Active Status Light submenu in the Hardware Validation
menu, or by clearing the error code log.
Содержание TRM 811.v2
Страница 1: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 1 Service Manual...
Страница 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 93...
Страница 104: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 104 Exploded View...
Страница 105: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Страница 106: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 106...
Страница 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 107...
Страница 108: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 108...
Страница 109: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 109...
Страница 110: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 110...