C944 Treadmill
Page 30
Procedure 6.2 - Replacing the Limit Switches, Actuator Shaft
or Switch Bracket
Note:
The limit switches and the actuator shaft are mounted on the switch bracket (see Diagram 4.2).
WARNING
Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood.
Procedure
1.
Remove the hood.
2.
If you are removing the actuator shaft
...
THEN...
OTHERWISE...
Skip to Step 12 (to remove the actuator
Continue with the next step.
shaft), Step 6 (to remove
the down limit switch) or Step 9 (to
remove the zero sense switch.
Removing the Upper Limit Switch
WARNING
When power is applied to the treadmill, the wires connected to the upper and lower limit switches
carry high voltage. Turn off the treadmill and unplug the power cord from the wall outlet before
you perform the following steps.
3.
Carefully remove the red wires from the upper limit switch.
Note:
See Diagram 6.2 for limit switch wiring.
4.
Remove the screws and washers that secure the limit switch to the switch bracket.
5.
If you are removing more than one limit switch
...
THEN...
OTHERWISE...
Continue with the next step to
Skip to Step 11.
remove the down limit switch or
Step 9 to remove the zero sense
switch
Содержание c944
Страница 39: ...C944 Treadmill Page 39 Wiring Diagram 7 1 C944 SCR 120 Vac J9...
Страница 40: ...C944 Treadmill Page 40 Block Diagram 7 2 C944 SCR 120 Vac...
Страница 42: ...C944 Treadmill Page 42 Block Diagram 7 4 C944 SCR 240 Vac...
Страница 43: ...C944 Treadmill Page 43 Wiring Diagram 7 5 C944 PWM 120 Vac F1 Lift Fuse 2A Slow Blow...
Страница 44: ...C944 Treadmill Page 44 Block Diagram 7 6 C944 PWM 120 Vac...
Страница 45: ...C944 Treadmill Page 45 Wiring Diagram 7 7 C944 PWM 240 Vac F1 Lift Fuse 2A Slow Blow...
Страница 46: ...C944 Treadmill Page 46 Block Diagram 7 8 C944 PWM 240 Vac...