C576i Self Powered Elliptical Fitness Crosstrainer
Page 43
Procedure 7.5
- Replacing the Upper or Lower Interconnect Cables
Before you install a new interconnect cable, ensure that the interconnect cable is defective as
described in Procedure 6.1.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
1.
Attach the wrist strap to your arm, then connect the ground lead of the wrist strap to the EFX
frame.
Replacing the Upper Interconnect Cable
2.
Remove the display housing per Procedure 7.3.
3.
The upper and lower interconnect cables are connected behind the access cover below the
the display. Refer to Diagram 6.1.
4.
Disconnect the upper interconnect cable from the mid-point connector. Tape the end of the
replacement interconnect cable with the to the upper end of the old interconnect cable
(display housing end).
5.
Carefully pull the old interconnect cable out of the mid-point access hole while feeding the
new interconnect cable into the unit. When the new cable is fully into the unit, remove the
tape and discard the old interconnect cable. Connect the upper interconnect cable to the
mid-point connector and push them into the access hole.
6.
Connect the upper interconnect cable to the upper PCA. Replace the display housing per
Procedure 7.3.
7.
Remove the ground lead of the wrist strap from the EFX frame, then remove the wrist strap
from your arm.
8.
Check the operation of the EFX as described in Section Four.
Replacing the Lower Interconnect Cable
9.
Remove the right side rear cover per Procedure 7.1. Disconnect the interconnect cable from
the lower PCA (connector J2). Refer to Diagram 7.7.
10. The upper and lower interconnect cables are connected behind the access cover below the
the display. Refer to Diagram 6.1.
11. Disconnect the lower interconnect cable from the mid-point connector. Tape the
replacement interconnect cable to the old interconnect cable at the lower PCA end of the old
interconnect cable.