background image

 

 

 

TwinTemp

 

2/

 

Jr.

 

Diagnostics

 

&

 

Trouble

 

Shooting

  

A.

 

Use

 

Rhogard

 

Boiler

 

antifreeze

 

with

 

Protek

 

922

 

additive

 

or

 

equivalent

 

with

 

Aluminum

 

tank.

  

Camco

 

is

 

acceptable

 

with

 

stainless

 

steel

 

tank.

  

1.

 

Mix

 

antifreeze

 

50/50

 

with

 

distilled

 

water

 

2.

 

Total

 

amount

 

of

 

antifreeze

 

held

 

in

 

hydronic

 

system

 

of

 

a

 

Newmar

 

coach

 

is

 

approximately

 

5.5

 

gal.

 

3.

 

Always

 

check

 

fluid

 

level

 

and

 

condition.

 

4.

 

Common

 

cause

 

of

 

contamination;

  

a.

 

Repeated

 

introduction

 

of

 

air

 

in

 

closed

 

system

 

causing

 

fluid

 

contamination.

  

b.

 

Plumbing

 

leaks,

 

radiator

 

cap,

 

etc.

 

c.

 

 

Do

 

not

 

mix

 

winterizing

 

afrz.

 

or

 

ethylene

 

glycol

 

afrz.

 

with

 

propylene

 

glycol

 

boiler

 

antifreeze.

 

d.

 

Effects

 

of

 

contamination,

 

sludge,

 

metal

 

corrosion.

 

B.

 

 

Starting

 

diagnostics

 

check

 

basics;

 

power,

 

fault

 

codes,

 

etc.

  

then

 

use

 

the

 

sequence

 

of

 

operation

 

to

 

aid

 

diagnostics.

 

1.

 

Two

 

calls

 

for

 

ignition,

 

Antifreeze

 

temperature

 

(tank

 

thermostat

 

switch)

 

and

 

interior

 

thermostat.

 

C.

 

Causes

 

and

 

symptoms

 

of

 

restricted

 

flow.

 

1.

 

Sludge/restriction

 

in

 

plumbing

 

loop.

 

2.

 

Kinked

 

plumbing

 

lines

 

or

 

connections.

 

3.

 

Sounds

 

associated

 

with

 

restricted

 

flow

 

are

 

rattling

 

knocking

 

noise

 

during

 

propane

 

ignition

 

with

 

ignition

 

only

 

lasting

 

10

20

 

seconds.

  

Содержание TWINTEMP JR.

Страница 1: ...TWINTEMP JR HYDRONIC SYSTEM 2 2013...

Страница 2: ...rner will not light The solenoid gas valve is energized and a spark is effected to the igniter probe over burner via the yellow ignition wire The flame is proofed via the same igniter element and yell...

Страница 3: ......

Страница 4: ......

Страница 5: ...eeded 3 Performance test heating and hot water functions 4 Check interior and exterior plumbing connections for fluid leak 5 Check propane connections for leaks 6 Check boiler antifreeze level in over...

Страница 6: ...d contamination b Plumbing leaks radiator cap etc c Do not mix winterizing afrz or ethylene glycol afrz with propylene glycol boiler antifreeze d Effects of contamination sludge metal corrosion B Star...

Страница 7: ...mp thermostat and blower signal goes to the bank of relays and then distributed to the coach wiring F Summer winter valve positions G Electric element operation 1 Used as stand alone for limited hot w...

Страница 8: ...ction of the TwinTemp is not needed the heated anti freeze should not be circulated to the blowers To prevent this circulation the Summer Winter by pass valve should be turned turn When heating is aga...

Страница 9: ...em is required in winter mode for hot water production due to 3 gallons of cold fluid in the hydronic loop suddenly being returned to the TwinTemp tank lowering the fluid boiler antifreeze temperature...

Отзывы: