TWINTEMP

 

JR.

 

HYDRONIC

 

SYSTEM

 

2/2013

 

 

 

 

 

 

 

 

 

Содержание TWINTEMP JR.

Страница 1: ...TWINTEMP JR HYDRONIC SYSTEM 2 2013...

Страница 2: ...rner will not light The solenoid gas valve is energized and a spark is effected to the igniter probe over burner via the yellow ignition wire The flame is proofed via the same igniter element and yell...

Страница 3: ......

Страница 4: ......

Страница 5: ...eeded 3 Performance test heating and hot water functions 4 Check interior and exterior plumbing connections for fluid leak 5 Check propane connections for leaks 6 Check boiler antifreeze level in over...

Страница 6: ...d contamination b Plumbing leaks radiator cap etc c Do not mix winterizing afrz or ethylene glycol afrz with propylene glycol boiler antifreeze d Effects of contamination sludge metal corrosion B Star...

Страница 7: ...mp thermostat and blower signal goes to the bank of relays and then distributed to the coach wiring F Summer winter valve positions G Electric element operation 1 Used as stand alone for limited hot w...

Страница 8: ...ction of the TwinTemp is not needed the heated anti freeze should not be circulated to the blowers To prevent this circulation the Summer Winter by pass valve should be turned turn When heating is aga...

Страница 9: ...em is required in winter mode for hot water production due to 3 gallons of cold fluid in the hydronic loop suddenly being returned to the TwinTemp tank lowering the fluid boiler antifreeze temperature...