Burner Ignites But Water Temperature Is too low

1. The water flow may be so high as to exceed the 

capacity of the heater particularly if your supply 
water is very cold. Slow the water flow.

2. The gas pressure may be too low. Be sure the 

tanks are full and tank selector is not in center  
position.

3. Check the dynamic gas pressure while the water is 
on at full flow. The LPG pressure should be the 
“manifold pressure” as shown on the specification 
label while the heater is running. A gas-testing gauge 
should be installed on the manifold tap so that it may 
be read while heater is running. If it is too low, turn up 
the gas regulator to the proper pressure. Regulator 
may be defective and needs to be replaced.  This 
should only be done by a qualified technician.
4. The gas flow may be too low due to improper gas 
line diameter (under 3/8 inch outside diameter). The 
gas line may be excessively long (over 20-30 feet) or 
the on/off solenoid at the tank (if you have one) may 
have an orifice that is too small (under 3/16th of an 
inch).
5. Check the heater air inlet openings and flue pipe 
for airflow obstructions and clean.
6. Check that the “summer / winter” valve is in the 
proper position for the temperature of the incoming 
water.

Water Temperature Too Low at Lower Water Flow 
Rates

1. Check that the “summer / winter” valve is in the 
proper position for the temperature of the incoming 
water.
2.  Be sure to momentarily turn water flow to high, 
then back to the lower flow when turning on a water 
faucet.  This will bring the gas flow to the required 
higher setting.

Water Temperature Is Too Hot or No Temperature 
Control.

1. Fuel tank regulator is set too high and manifold 
pressure as described above Have the regulator 
checked by a qualified technician.  
2.  Check that the “summer / winter” valve is in the 
proper position for the temperature of the incoming 
water.
3. Water flow too low for incoming water temperature.

Low Heat Rise and Excessive Water Flow Is 
Required To Trigger Water Heater

If you find that your heater requires excessive flow to 
activate it (much over .5 gallon per minute), it is likely 
that you have cold water bleeding into the hot water 
side of your water system.
1.  Check that valves and faucets are closed when 
not in use. If there is an on/off button on your shower 
head, always turn the water valves off after the 
shower to prevent cold water from bleeding into the 

hot water system. This will keep the heater from 
functioning properly.

2. Be sure that the bypass valve at the water plumbing 
connections is in the "off" position.  An open valve can 
also permit water to bypass heater, causing it not to fire.

If any problem persists, contact an 

PrecisionTemp

.

 

PrecisionTemp, Inc.

 WATER HEATER 

LIMITED WARRANTY

PrecisionTemp, Inc warrants to the original owner and subject to the
below mentioned conditions, that this product will be free of defects in
material or workmanship for a period of two years from the original date of 
purchase. PrecisionTemp’s liability hereunder is limited to the replacement of the 
product, repair of the product, or replacement of the product with a reconditioned 
product at the discretion of the manufacturer. This warranty is void if the product 
has been damaged by accident, unreasonable use, neglect, tampering or other 
causes not arising from defects in material workmanship.
This warranty extends to the original owner of the product only and is
subject to the following conditions:
1. For a period of two years from the date of purchase, PrecisionTemp will replace 
the complete water heater if the heat exchanger leaks due to corrosion.  This 
warranty includes reasonable labor charges required to
replace the complete water heater.
2. For two years from the date of purchase, PrecisionTemp will repair or replace 
any part defective in material or workmanship. This warranty includes reasonable 
labor charges, required to remove and replace the part.  Service calls to 
customer’s location are not considered part of these
charges and are, therefore, the responsibility of the owner.
3. This warranty does not cover the following items classified as normal
maintenance:
a. adjustment of gas pressure
b. cleaning or replacement of burner orifices
c. cleaning or adjustment of burner assembly
d. cleaning or adjustment of flue
e. adjustment of pressure relief valve
4. 

In the event of a warranty claim, the owner must contact, in 

advance, either an authorized PrecisionTemp Service Center or the 
PrecisionTemp Service Department. Warranty claim service must be 
performed at an authorized PrecisionTemp Service Center (a list will be 
provided at no charge) or as approved

, PrecisionTemp, Inc 

11 Sunnybrook Dr. Cincinnati, OH 45237, 800-934-9690 Ext. 109. Return parts (or 
water heater) must be shipped to PrecisionTemp “Prepaid”. The defective parts (or 
water heater) become the property of PrecisionTemp and must be returned to the 
Service Department,
PrecisionTemp, Inc. 11 Sunnybrook Dr. Cincinnati, OH 45237.
6. This warranty applies only if the unit is installed according to the installation 
instructions provided and complies with local and state codes.
7. The warranty period on replacement parts (or water heater) is the
unused portion of the original warranty period or ninety (90) days,
whichever is greater.
8. Damage or failure resulting from misuse (including failure to seek proper repair 
service), misapplication, alterations, water damage, or freezing are the owner’s 
responsibility.
9. PrecisionTemp does not assume responsibility for any loss of use of vehicle, 
loss of time, inconvenience, expense for gasoline, telephone, travel, lodging, loss 
or damage to personal property or revenues. Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above 
limitations or exclusions may not apply to you.
10. Any implied warranties are limited to two (2) years. Some states do not allow 
limitations on how long an implied warranty lasts, so the above limitation may not 
apply to you. This warranty gives you specific legal rights and you may also have 
other rights which vary from state to state.
11. Replacement parts purchased outside of the original water heater warranty 
carry a 90 day warranty. This includes the part at no charge.

This PrecisionTemp heater is designed for use in recreational vehicles, park 
models, mobile food carts and marine applications for the purpose of heating water 
as stated in the “data plate” attached to the water heater. Any other use, unless 
authorized in writing by the PrecisionTemp Engineering Department, voids this 
warranty.

11 Sunnybrook Drive
Cincinnati, OH. 45237
Phone: 513-641-4446 * 800-934-9690
Fax:      513-641-0733
www.precisiontemp.com

Содержание ShowerMate-550

Страница 1: ...e responsible for anything that is a result of non compliance FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING...

Страница 2: ...he heater as close to the gas supply as practical to minimize length of the gas line Although the ShowerMate can be mounted with zero clearance around the sides top and bottom be sure that the install...

Страница 3: ...l It must be mounted well above the waterline while keeping the flue pipe run under 10 If PrecisionTemp s optional mushroom vent is used it can be mounted on a vertical or horizontal surface It must b...

Страница 4: ...codes Standard on Recreational Vehicles ANSI A119 2 or CAN CSA Z240RV excessive heat If you use a discharge line do not use a reducing coupling or other restriction smaller than the outlet of the rel...

Страница 5: ...T REMAIN TURNED ON This allows the burner to fire and electric elements to protect the system Any freezing of the water heater or other plumbing components can cause severe damage that is not covered...

Страница 6: ...t 2454 3 Igniter 3328 4 Pressure Relief Valve 1375 5 Modulating Valve Assembly 3381 6 Gas Valve 1073 8 Blower Relay 3619 9 Water Inlet Tube 3545 10 Gas Inlet Tube 3223 11 Ignition Control 3359 14 Vacu...

Страница 7: ...When Water Is On Power vent is running 1 Be sure the gas valve at the tank is On there is gas in the tank and the gas line is purged of all air 2 Be sure that flue terminus is not blocked 3 Check that...

Страница 8: ...unreasonable use neglect tampering or other causes not arising from defects in material workmanship This warranty extends to the original owner of the product only and is subject to the following cond...

Отзывы: