Making Connections

1. Connect plumbing to water lines taking care to make correct “COLD” and “HOT” orientation.  
2. Connect 3/8” FM flared LP gas line to 3/8” M flared gas fitting. Hand tighten initial connection to 

assure it is not cross-threaded, then tighten with wrench while backing up fitting with a second 
wrench.  

Note:

 This flare fitting is a “dry” fitting, meaning no pipe dope of tape should be used 

when making the connection.  The gas line should be an approved type of one, continuous, 
unbroken line from the propane locker to the appliance.

3. Turn on the gas and check the water heater and all connections for gas leaks with a leak detecting 

solution.  Never use a flame to check for gas leaks.

4. Turn on water supply line and check for water leaks.

 WARNING : 

NEVER install heater in a manner that is not vented to the outside. Doing so will void the 

warranty and cause the heater to malfunction and could result in serious injury or death. Terminus of 

flue outside boat should be above the water line.

Flue Pipe Installation

Cold In

Hot Out

Gas Connection

 12

VDC

2” Flue pipe 
Connection

 

After the unit is secured into place, the exhaust pipe is installed as follows:
1. Locate and install the flue terminus on the outside of the vessel.  It must be mounted well above 

the waterline, while keeping the flue pipe run under 10’. If PrecisionTemp’s optional mushroom 
vent is used, it can be mounted on a vertical or horizontal surface.  It must be located so that no 
water can enter the flue system and no flue gasses can re-enter the living area through hatches 
or other air intakes.

2. Carefully measure and cut one, continuous length of flex flue pipe to run from the 2” flue pipe on 

the top of the appliance to the flue terminus.  Keep length and bend of the pipe to a minimum.  
2” stainless flex duct is recommended.  Never use galvanized or CPVC pipe.

3. Now remove the pipe and coat the inside diameter of the flue pipe elbow with high temperature 

silicone sealant or equivalent.  

4. Attach either end of the flex pipe to the appliance outlet and the flue terminus. This can be done 

with self-tapping screws or by pre-drilling the hole before inserting metal screws.  At least two 
screws must be used to secure the pipe.  

NOTE:

  The appliance must be disconnected from the gas supply piping system 

during any pressure testing of the system at test pressures in excess of 

½

 psi. The 

appliance must be isolated from the gas piping system during any pressure testing at 

test pressures equal to or less than 

½

 psi. Pressure inlet to valve, 13” W.C. maximum, 

11” W.C. minimum. Pressure at outlet of valve is factory set at 10”. Burner manifold 

pressure is W.C. 8.9” W.C. +/- .2” at tap on burner manifold.

Содержание ShowerMate-550

Страница 1: ...e responsible for anything that is a result of non compliance FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING...

Страница 2: ...he heater as close to the gas supply as practical to minimize length of the gas line Although the ShowerMate can be mounted with zero clearance around the sides top and bottom be sure that the install...

Страница 3: ...l It must be mounted well above the waterline while keeping the flue pipe run under 10 If PrecisionTemp s optional mushroom vent is used it can be mounted on a vertical or horizontal surface It must b...

Страница 4: ...codes Standard on Recreational Vehicles ANSI A119 2 or CAN CSA Z240RV excessive heat If you use a discharge line do not use a reducing coupling or other restriction smaller than the outlet of the rel...

Страница 5: ...T REMAIN TURNED ON This allows the burner to fire and electric elements to protect the system Any freezing of the water heater or other plumbing components can cause severe damage that is not covered...

Страница 6: ...t 2454 3 Igniter 3328 4 Pressure Relief Valve 1375 5 Modulating Valve Assembly 3381 6 Gas Valve 1073 8 Blower Relay 3619 9 Water Inlet Tube 3545 10 Gas Inlet Tube 3223 11 Ignition Control 3359 14 Vacu...

Страница 7: ...When Water Is On Power vent is running 1 Be sure the gas valve at the tank is On there is gas in the tank and the gas line is purged of all air 2 Be sure that flue terminus is not blocked 3 Check that...

Страница 8: ...unreasonable use neglect tampering or other causes not arising from defects in material workmanship This warranty extends to the original owner of the product only and is subject to the following cond...

Отзывы: