Burner Ignites But Water Temperature Is too low
1. The water flow may be so high as to exceed the
capacity of the heater particularly if your supply
water is very cold. Slow the water flow.
2. The gas pressure may be too low. Be sure the gas
flow control valve is in full “on” position.
3. Check the gas pressure while the water is on at full
flow. The LPG pressure should be the “manifold
pressure” as shown on the specification label while the
heater is running. A gas-testing gauge should be
installed on the manifold tap so that it may be read
while heater is running. If it is too low, turn up the gas
regulator to the proper pressure. This should only be
done by a qualified technician.
4. The gas flow may be too low due to improper gas
line diameter (under 3/8 inch outside diameter). The
gas line may be excessively long (over 20-30 feet) or
the on/off solenoid at the tank (if you have one) may
have an orifice that is too small (under 3/16th of an
inch).
5. Check the heater door louvers and flue pipe for
airflow obstructions and clean.
6. Check that the “summer / winter” valve is in the
proper position for the temperature of the incoming
water.
Water Temperature Too Low at Lower Water Flow
Rates
1. Check that the “summer / winter” valve is in the
proper position for the temperature of the incoming
water.
2. Be sure to momentarily turn water flow to high, then
back to the lower flow when turning on a water faucet.
This will bring the gas flow to the required higher
setting.
Water Temperature Is Too Hot or No Temperature
Control.
1. Fuel tank regulator is set too high and manifold
pressure as described above Have the regulator
checked by a qualified technician.
2. Check that the “summer / winter” valve is in the
proper position for the temperature of the incoming
water.
3. Water flow too low for incoming water temperature.
Low Heat Rise and Excessive Water Flow Is
Required To Trigger Water Heater
If you find that your heater requires excessive flow to
activate it (much over .5 gallon per minute), it is likely
that you have cold water bleeding into the hot water
side of your water system.
1. Check that valves and faucets are closed when not
in use. If there is an on/off button on your showerhead,
always turn the water valves off after the shower to
prevent cold water from bleeding into the hot water
system. This will keep the heater from functioning
properly.
2. Be sure that the bypass valve at the water plumbing
connections is in the "off" position. An open valve can also
permit water to bypass heater, causing it not to fire.
If any problem persists, contact an authorized service
center or
PrecisionTemp
.
PrecisionTemp, Inc.
WATER HEATER
LIMITED WARRANTY
PrecisionTemp, Inc warrants to the original owner and subject to the
below mentioned conditions, that this product will be free of defects in
material or workmanship for a period of two years from the original date
of purchase. PrecisionTemp’s liability hereunder is limited to the
replacement of the product, repair of the product, or replacement of the
product with a reconditioned product at the discretion of the
manufacturer. This warranty is void if the product has been damaged by
accident, unreasonable use, neglect, tampering or other causes not
arising from defects in material workmanship.
This warranty extends to the original owner of the product only and is
subject to the following conditions:
1. For a period of two years from the date of purchase, PrecisionTemp
will replace the complete water heater if the heat exchanger leaks due to
corrosion. This warranty includes reasonable labor charges required to
replace the complete water heater.
2. For two years from the date of purchase, PrecisionTemp will repair or
replace any part defective in material or workmanship. This warranty
includes reasonable labor charges, required to remove and replace the
part. Service calls to customer’s location are not considered part of these
charges and are, therefore, the responsibility of the owner.
3. This warranty does not cover the following items classified as normal
maintenance:
a. adjustment of gas pressure
b. cleaning or replacement of burner orifices
c. cleaning or adjustment of burner assembly
d. cleaning or adjustment of flue
e. adjustment of pressure relief valve
4.
In the event of a warranty claim, the owner must contact, in
advance, either an authorized PrecisionTemp Service Center or the
PrecisionTemp Service Department. Warranty claim service must be
performed at an authorized PrecisionTemp Service Center (a list will be
provided at no charge) or as approved
, PrecisionTemp, Inc
11 Sunnybrook Dr. Cincinnati, OH 45237, 800-934-9690 Ext. 109.
Return parts (or water heater) must be shipped to PrecisionTemp
“Prepaid”. The defective parts (or water heater) become the property of
PrecisionTemp and must be returned to the Service Department,
PrecisionTemp, Inc. 11 Sunnybrook Dr. Cincinnati, OH 45237.
6. This warranty applies only if the unit is installed according to the
installation instructions provided and complies with local and state
codes.
7. The warranty period on replacement parts (or water heater) is the
unused portion of the original warranty period or ninety (90) days,
whichever is greater.
8. Damage or failure resulting from misuse (including failure to seek
proper repair service), misapplication, alterations, water damage, or
freezing are the owner’s responsibility.
9. PrecisionTemp does not assume responsibility for any loss of use of
vehicle, loss of time, inconvenience, expense for gasoline, telephone,
travel, lodging, loss or damage to personal property or revenues. Some
states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not
apply to you.
10. Any implied warranties are limited to two (2) years. Some states do
not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. This warranty gives you specific legal
rights and you may also have other rights which vary from state to state.
11. Replacement parts (components or tanks) purchased outside of the
original water heater warranty carry a 90 day warranty. This includes
the part at no charge.
This PrecisionTemp heater is designed for use in recreational vehicles for
the purpose of heating water as stated in the “data plate” attached to the
water heater. Any other use, unless authorized in writing by the
PrecisionTemp Engineering Department, voids this warranty.
11 Sunnybrook Drive
Cincinnati, OH. 45237
Phone: 513-641-4446 * 800-934-9690
Fax: 513-641-0733
www.precisiontemp.com