PrecisionTemp RV-550 Скачать руководство пользователя страница 4

1)

Pressurize the water system by turning on pump or city  
water pressure.

2)

Purge all air from the system by turning on the faucets 
until a steady stream of water flows.

3)

Turn on the 12V DC power supply.

4)

Turn on the LP supply at the tank and the manual gas 
valve (if installed).The water heater will remain 
dormant until a water tap is opened and the heater 
senses water flow of at least 0.5 GPM.

5)

Turn on the hot water tap to full open. The heater will 
fire up within several seconds and hot water will flow 
from the tap in the time it takes to traverse the lines 
from the heater to the faucet. (If this is the first usage, 
you may have to turn the water on and off several 
times to purge the LP gas lines of air. If the heater fails 
to light or the lockout lamp (optional) illuminates, turn 
the power switch OFF, then ON to reset the ignition 
control. After ignition water flow can be reduced cold 
water added as desired. 

6)

To shut off the water heater, shut off the water. Shut off 
power at remote switch or breaker.

7)

Should overheating occur or the gas supply fail to shut 
off, turn off the “ON/OFF” power switch.

A Note About “Navy Showers” When Dry Camping

It is recommended to take a shower just like you would at 
home.  That is, leave the water running through the entire 
shower.  The hot water system is designed to deliver a 
continuous, comfortable flow of hot water and that’s the 
way it works best.  

Shutting off the shower with the showerhead button 
wastes water.  Each time this is done, the showerhead 
“trickles”, filling the hot water line with cold water. This 
cold water has to be purged from the line each time the 
showerhead is turned back on.  Tests have shown that 
this will not save water and sometimes uses more water 
than leaving the shower run continuously

Winter Operation and Winterizing Water Heater

This heater is equipped with freeze protection that will 
prevent freezing under most conditions.  In order for it to 
function, 12 VOLT AND GAS SUPPLY MUST REMAIN 
TURNED ON.  This allows the burner to fire and electric 
elements to protect the system.   Any freezing of the 
water heater or other plumbing components can cause 
severe damage that is not covered by warranty.

Winter Traveling Operation:

In some areas all LPG appliances must remain off

when coach is in motion.  If this is the case, drain 

heater as follows:

1.

Turn off water pump and the power and gas to the 
heater. Open the pressure relief valve by lifting the 
handle to a 90° position from the normal position.

2.

Summer / Winter valve should be turned to 
“SUMMER” position. 

3. Open drain valve that was installed at hot water outlet 
fitting of heater.
4. Open at least one hot and cold water tap in the 
coach. This should drain the system. 

Winterizing Procedure:

Before storing the system for the winter, the plumbing 
system must be winterized. This can be done by either 
of the following methods:
1. All water should be drained from the system. To do 
this, open one tap at a time using compressed air to 
purge the system of all water.
2. Recommendations of your coach manufacturer 
should be followed. The water system can be filled with 
RV, non-toxic anti-freeze. When you see the anti-freeze 
coming from the hot water tap, the heater is protected

.

Temperature Adjustment

Outlet water temperature can be adjusted by turning the 
“Summer / Winter” up 1/4 turn. Full vertical is the 
warmest position and full horizontal is the coolest 
position.

     
“Summer / Winter” valve in “Summer” position

4

Содержание RV-550

Страница 1: ...to obtain service information Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Evacuate all persons from th...

Страница 2: ...se holes with no gaps or openings where the line passes through the case All connections must be made using TWO 2 wrenches to avoid twisting and damaging lines Damage voids the Warranty 5 Erect the si...

Страница 3: ...up Before making the connections turn the switch to the OFF position PRESSURE RELIEF VALVE THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR ANY REASON OTHER THAN REPLACEMENT This water he...

Страница 4: ...showerhead is turned back on Tests have shown that this will not save water and sometimes uses more water than leaving the shower run continuously Winter Operation and Winterizing Water Heater This h...

Страница 5: ...XH 2XWOHW 6FUHHQ OXH 7XEH 3UHVVXUH 6ZLWFK ORZHU VVHPEO DQ DVH OXH RRG VVHPEO DVH VVHPEO HDW FKDQJHU 2 3OXJ 2ULILFH WX 2ULILFH WX 2ULILFH WX 3UHVVXUH OERZ 16 6WDQGDUG RRU LW RORU 5HT 16 DUJH RRU LW ROR...

Страница 6: ...An open valve can also permit water to bypass heater causing it not to fire There Is No Ignition When Water Is On Power vent is running 1 Be sure the gas valve at the tank is On there is gas in the t...

Страница 7: ...le use neglect tampering or other causes not arising from defects in material workmanship This warranty extends to the original owner of the product only and is subject to the following conditions 1 F...