IMPORTANT SAFETY ADVICE

• Ensure that an approved carbon monoxide detector 
(BS EN50291:2001) is fitted in the same room as the 
stove. It should be powered by a battery designed for 
the working life of the alarm. 

Please note

 this is now a 

requirement under UK Building Regulations.
• External surfaces including the fire chamber door 
and operating handles, windows and stove bodywork  
will become extremely hot. Always use the tool 
provided and avoid touching these parts of the stove 
without proper protection, such as heat-resistant 
gloves or other protective aids. 
• Potentially combustible material or objects such as 
soft furnishings should never be left on or near any 
of the stove’s hot surfaces. Ensure that wood supplies 
and log baskets are kept at a safe distance from the 
stove. See Minimum Distance to Combustibles page 3.
• Never leave children unattended in the room where 
your stove is being operated. Ensure that children are 
aware of the potential danger and make sure that 
they keep clear of the stove when it is in operation. 
Where children, the elderly or the infirm are present 
always use an approved safety fireguard (BS6539) to 
prevent accidental contact with the stove. 
• This stove should 

not

 be fitted in a room with an 

extractor fan (eg kitchen) as this will adversely effect 
the air quality in the room and could be dangerous for 
the room’s occupants. It will also starve the stove of 
combustion air and reduce the stove’s efficiency.
• To ensure your safety make sure that your stove’s 
installation complies with all local, national and  
European building regulations’ ventilation requirements.  
Low energy houses have their own particular  
requirements and these should be strictly adhered to.
• Do not use flammable liquids to ignite the fire. In 
the confined space of the stove’s fire chamber there is 
a real potential to cause a life-threatening flash flame 
or explosion.
• Never over-fire the stove. If any external parts of 
your stove glow red during operation then immediate 
action should be taken to reduce the supply  
of combustion air to the fire chamber through the  
Primary and Secondary Air controls which should 
quickly limit the intensity of the fire.
• This stove is CE approved and tested to EU EN13229 
standards in the United Kingdom by Kiwa GasTec at 
CRE of Stoke Orchard, Gloucestershire. Alterations to 
its construction could be potentially dangerous and 
will also render your product warranty void.
• Do not use aerosol products in the vicinity of the 
stove when it is in use.
• Check and clean the stove’s flue way and the top 
of the baffle plate regularly to help avoid potential 
blockages.
• Clean your chimney regularly.

BOILER STOVE SYSTEMS – 

SPECIFIC SAFETY ISSUES

• This stove requires a dedicated non-closable air 
vent of the appropriate size for its maximum heat 
output and this should be located in the same room 
as the stove. An adequate supply of combustion air 
is essential for the safe operation of this stove – see 
page 5 for maximum outputs.
• The system should not rely solely on gravity fed 
circulation but must also incorporate a circulation 
pump. 
• This stove should not be connected directly to a 
sealed or pressurised system without including a 
safety ‘buffer’ between the systems such as a thermal 
store, heat exchanger or specialist link-up component. 
This will also help neutralise any pipe size difference 
between the two systems which could adversely affect 
performance.
•The cold feed and open vent flows must not be 
fitted with any manual or automatic valve. The system 
flow must not be able to be ‘closed off’ so that there 
is always a clear flow route from the stove to the 
system’s open vent
• In the event of a power cut or circulation pump 
failure your stove will continue to produce hot 
water which could be potentially dangerous. Your 
system design should therefore provide for the safe 
dissipation of excess hot water through a heat loss or 
heat leak radiator. 
• Motorised valves must revert to the open position in 
the event of a power failure. This will allow heat to be 
safely dissipated through the system’s natural gravity 
circulation process.
• Although it is common practice for heat leak 
radiators to be located in an upstairs bathroom it is 
worth noting that on some boiler stove systems the 
heat leak radiator can get very hot and therefore we 
recommend installing a low surface temperature type 
radiator and / or locating it where young children or 
the infirm won’t accidentally come into contact with it
• The heat output to water from this boiler stove must 
not be significantly greater than any potential usage. 
The system’s heat release feature, especially if linked, 
must be sufficient to prevent the system from over-
heating.
• The system design must incorporate a drain point, 
preferably near the boiler stove, and be sufficient 
to empty the system of any residue water during 
maintenance or removal.
• All electrical connections, for example to system 
valves, the circulating pump and the link-up 
component must comply with current Building 
Regulations. Ensure that the pipework is correctly 
earthed. See page 7 for relevant regulations. 
• The mains water connection to the system must 

Содержание HF357i-B

Страница 1: ...t operation You will need to refer to the serial number of your stove should you ever need to make a claim under the Horse Flame Warranty You will nd the serial number beginning with HF on the CE plat...

Страница 2: ......

Страница 3: ...herefore some of the stove photographs and diagrams used which are used for guidance purposes only may differ slightly from your new Precision Inset Boiler stove However the principles illustrated her...

Страница 4: ...IONS 4 Vertical view L H Side view Vertical view L H Side view Vertical view L H Side view All sizes in mm Vertical view L H Side view Vertical view L H Side view Vertical view Vertical view L H Side...

Страница 5: ...ominal Heat Output To Room 4 8 kW To Water 7 5 kW TOTAL 12 3 kW Ef ciency net 80 2 Mean CO Emission at 13 0 52 Mean Flue Gas Temperature 296 C Flue Gas Mass Flow 7 0 g s MINERAL FUELS Ancit Continuous...

Страница 6: ...e stove when it is in use Check and clean the stove s ue way and the top of the baf e plate regularly to help avoid potential blockages Clean your chimney regularly BOILER STOVE SYSTEMS SPECIFIC SAFET...

Страница 7: ...he Government to approve solid fuel domestic heating appliances and the registration of competent installers HETAS registered installers in England and Wales can self certi cate their work thus avoidi...

Страница 8: ...e found here www smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of Smoke Control Areas and you can contact...

Страница 9: ...and the access to the ue way to avoid potential soot build up and blockages Once you know how to do this it is a very easy operation See page 10 Flue spigot plate To maximise ef ciency and safety the...

Страница 10: ...shes To back of stove 3 Carefully remove from the re chamber 2 Drop down at angle 1 Push upwards and pull forward such as porous stonework tile grout or carpets as there will inevitably be some sooty...

Страница 11: ...and chimney Unpleasant smoky smells both inside and sometimes outside the house In the event of a problem with your stove always check your choice of fuel rst Manufactured or nished wood products such...

Страница 12: ...ntrol the different types of combustion air that wood and mineral fuels need Your new stove can burn very well or very poorly depending on how you light the re how you refuel the re and of course the...

Страница 13: ...ds placed against the boiler sides restrict combustion and can create unwanted cold spots in both the log and the water As the end grain of the wood produces more of the remaining moisture and gases w...

Страница 14: ...ckly set Wood burns best if the ames have other wood to play off For example a single dense piece of wood or log will not burn as well as 2 or 3 smaller logs of equivalent mass The more contact the wo...

Страница 15: ...s 1 Boiler stoves operate at a much lower temperature than non boiler stoves and consequently the potential to create soot or creosote build up in the ue system is also much greater especially when op...

Страница 16: ...nd the burn rate of the mineral fuel load and therefore the heat into the room To do this ensure the Primary and Secondary Air is fully closed Then simply control the ame pattern and burn rate with th...

Страница 17: ...building regulations it is also a requirement of your Warranty that the stove is installed by a competent person such as a Hetas or INFO registered installer who will be fully aware of any building a...

Страница 18: ...udes the edge of the ash lip As a general rule it is best to extend the hearth to at least 75mm 3 beyond the furthest out swing of the stove door if possible to avoid any potential live ash held on th...

Страница 19: ...e stoves create ue gases at a much greater temperature than those produced by an open re or gas appliance it does not necessarily follow that your chimney will function adequately or safely when your...

Страница 20: ...r to possess a knowledge and understanding which will be beyond the provisions and intentions of these general installation and operating guidelines The United Kingdom s Solid Fuel Association through...

Страница 21: ...21...

Страница 22: ...addition the hot water cylinder and heat leak radiator should be positioned as near to vertically above the boiler stove as possible and with suf cient height to encourage the natural ow Any horizonta...

Страница 23: ...the stove but also help avoid the potential build up of combustible soot along the sides this is an especially important requirement if you are not using a ue liner Some installations may require you...

Страница 24: ...the stove to the replace see below Carefully position the stove within the replace opening and mark the two holes on to the replace front Remove the stove and carefully drill the holes using the appr...

Страница 25: ...25 6 Legal Requirements Explain the householder s legal requirement to use an approved reguard when ever children or the elderly and the in rm are likely to be in the vicinity of the stove If the ins...

Страница 26: ...w it is extremely important that the radiators are balanced to ensure an ef cient distribution of heat as well as an even heat balance from one radiator to the next The idea is to reduce the ow to the...

Страница 27: ...or ue itself also needs cleaning Causes Inadequate supply of combustion air Check that any permanent air vent tted to supply the extra combustion air required for the stove has not been accidentally...

Страница 28: ...blackening of the glass should be considered a trade off In this instance if you re sure that the fuel from the stove they should only ever be speci ed tted and subsequently tested by an approved ins...

Страница 29: ...ikely to be a problem with the system The simplest way to determine this is if possible to check that the top water pipe from the stove is hot and that the lower pipe is cooler If this is the case the...

Страница 30: ...staining to build up as it will become more dif cult to remove after each ring When used regularly a proprietary scratch resistant stove glass cleaning gel or spray which can be supplied by your stove...

Страница 31: ...oprietary heat resistant re rope glue to secure the rope and glue both ends to ensure a well sealed joint The recommended rope seal diameter is 12mm Air ow through stove The heat from your inset stove...

Страница 32: ...be free from defective parts materials and workmanship at the time of purchase by the original consumer for a period of 1 year for components parts and labour excluding consumable parts and 5 years fo...

Страница 33: ...l parts for wear or damage and replace as necessary Re t all the internal parts Stove Glass Check the glass for chips or cracks and the glass seal condition and replace if necessary Thoroughly clean t...

Страница 34: ...ES AND SETTINGS For future reference include a basic drawing of the system and notes on the circulation pump and system thermostat settings etc as well as their location and the location of the system...

Страница 35: ......

Страница 36: ...ne Holmes Chapel Cheshire CW4 8AF United Kingdom Precision Multi Fuel Stoves 2010 2011 2012 and 2014 All rights reserved Booklet contents may not be copied in whole or in part without the prior writte...

Отзывы: