WARNING
Do not connect or disconnect under load.
Ensure driver has not been powered for a minimum of 1 minute before reconnecting the
LED module after disconnecting. Do not hot plug. Failure to follow this instruction will lead to
serious damage of the LED module and driver and will not be covered by warranty.
NOTE
LED module is not site serviceable.
Tampering will cause damage and will not
be covered by warranty.
NOTE
Maintain correct polarity when wiring. Incorrect wiring will cause serious damage and
will not be covered by warranty. Must be installed according to SELV regulations.
Wire specification: 22 AWG, ø0.65mm diameter double insulated teflon wire.
Red - Positive
Black - Negative
4. Remove fixture from ceiling
Hold the bezel and pull downwards.
Tilt fixture in direction of one of the
installation springs and continue to
pull down before straightening out the
fixture and pulling down until the fixture
is clear of the ceiling.
WARNING
caution springs can pinch
fingers. Handle with care.
Disconnect from driver.
WARNING
Ensure mains supply is off
before disconnecting luminaire.
Driver