PD6801 Explosion-Proof Loop-Powered  
Feet & Inches Level Meter 

Instruction Manual

 

 

PRECISION DIGITAL CORPORATION

 

 

233 South 

Street • Hopkinton MA 01748 USA 

Tel (800) 343-

1001 • Fax (508) 655-8990 

www.predig.com

 

 

 

 

  Fully-Approved Explosion-Proof Loop-Powered Meter 

  4-20 mA Input with ±0.03% Accuracy 

  3.0 Volt Drop (6.0 Volt Drop with Backlight) 

  Easy Field Scaling in Engineering Units without Applying an Input 

  0.6" (15.2 mm) Feet & Inches Upper Display With 1/8 or 1/16 Resolution 

  0.4" (10.2 mm) 7 Alphanumeric Characters Lower Display for Tag, Volume, or Percent 

  Display Level in Feet & Inches and Volume, Percent or Decimal Height Simultaneously 

  Display Mountable at 0°, 90°, 180°, & 270° 

  SafeTouch

TM

 Through-Glass Button Programming 

  20-Segment Tank Side Level Indicator Bargraph 

  Open Collector Output Assignable to High or Low Alarm 

  HART

®

 Protocol Transparent 

  Loop or External DC-Powered Backlight Standard 

  Operating Temperature Range: -40 to 75°C (-40 to 167°F) 

  FM Approved as Explosion-Proof / Dust-Ignition Proof / Flame-Proof 

  CSA Certified as Explosion-Proof / Dust-Ignition Proof / Flame-Proof 

  ATEX and IECEx Certified as Flame-Proof and Protection by Enclosure 

  Conformal Coated PCBs for Dust and Humidity Protection 

  Password Protection 

  32-Point Linearization 

  Wide Viewing Angle 

  Flanges for Wall or Pipe Mounting 

  Explosion-Proof, IP68, NEMA 4X Die-Cast Aluminum Enclosure  

  Two 3/4" NPT Threaded Conduit Openings (One Plug Installed)  

  2" U-Bolt Kits Available 

  3-Year Warranty 

 

 

 

Содержание Protex Pro PD6801

Страница 1: ...ously Display Mountable at 0 90 180 270 SafeTouchTM Through Glass Button Programming 20 Segment Tank Side Level Indicator Bargraph Open Collector Output Assignable to High or Low Alarm HART Protocol T...

Страница 2: ...All rights reserved Introduction The ProtEX F I PD6801 is a rugged explosion proof loop powered indicator specifically designed for level applications in hazardous areas or in the harshest environmen...

Страница 3: ...c ProtEX Approvals Overview The ProtEX Series carries extensive international approvals for hazardous areas https www predig com videos CTsNXQeRqTA ProtEX Enclosure Unique Features Learn about the uni...

Страница 4: ...Main Menu 14 Setting Up the Meter SETUP 15 Setting Numeric Values 15 Scaling the Meter SCaLe 16 Selecting Inch Fraction Display Mode FRACTN 16 Scaling the Tank Level Indicator PERCENT 16 Configuring t...

Страница 5: ...Dimensions Side Cross Section View 9 Figure 3 Connector Board 10 Figure 4 Connections without Backlight 11 Figure 5 Connections with Loop Powered Backlight 11 Figure 6 Connections with Externally Powe...

Страница 6: ...Mode Rejection 64 dB at 50 60 Hz Environmental Operating temperature range 40 to 75 C Storage temperature range 40 to 75 C Relative humidity 0 to 90 non condensing Connections Screw terminals accept...

Страница 7: ...40 C to 75 C Certificate number IECEx SIR 10 0056X Special Conditions for Safe Use Use suitably certified and dimensioned cable entry device and or plug The equipment shall be installed such that the...

Страница 8: ...ld be performed only by trained service personnel Service requiring replacement of internal components must be performed at the factory Disconnect from supply before opening enclosure Keep cover tight...

Страница 9: ...y part is missing or the meter malfunctions please contact your supplier or the factory for assistance Pre Installed Conduit Plug The PD6801 is supplied with one pre installed conduit plug for install...

Страница 10: ...20 mA signal return negative terminal connection when not using loop powered backlight BACKLIGHT 9 30 VDC when powering backlight from external supply BACKLIGHT 4 20 mA signal return negative termina...

Страница 11: ...ledge connections are made to two terminals labeled RESET Connect to a contact closure source such as a relay or a pushbutton as shown in Figure 7 Figure 7 External Alarm Reset Acknowledge Connections...

Страница 12: ...n Operation To actuate a button press and remove one finger to the glass directly over the marked button area Remove finger to at least 4 inches away from the glass in between button activations SafeT...

Страница 13: ...he meter Right Reset Button Press the Right arrow button to reset the maximum or minimum value while it is being displayed see Up Display Button below Press the Right arrow button to move to the next...

Страница 14: ...h 1 8th Set display for 1 8th inch fractions PERCENT Percent Scale the tank indicator full and empty values 0 PCT 0 Percent Set the tank empty value 100 PCT 100 Percent Set the tank full value DISPLAY...

Страница 15: ...nges made to settings prior to pressing ENTER are not saved Press the MENU button during Programming Mode to return to the previous menu selections Setting Numeric Values The numeric values are set us...

Страница 16: ...ling of the meter The minimum span is 0 10 mA Scale Error Message SPN ERR If the minimum span is not maintained the meter will show a span error SPN ERR and revert to input 2 allowing the appropriate...

Страница 17: ...arate second scale of the input process variable This is configured in Volume Display Scaling VOLSCAL on page 19 Percent full height shows the percent full of the tank height level indicator programme...

Страница 18: ...Medium Set noise filter to medium setting HI Filter High Set noise filter to high setting OFF Filter Off Disable noise filter VOLSCAL Volume Scale Scale the volume display NO PTS Number of Set the nu...

Страница 19: ...lay and ALARM until the alarm condition is cleared The alarm status will show on the display even if the output is not wired Input Signal Filter FILTER The noise filter is available for unusually nois...

Страница 20: ...moment while the meter is accepting the signal After the signal is accepted the meter displays 20 mA Apply a 20 000 mA signal and press ENTER The display flashes for a moment while the meter is accept...

Страница 21: ...he meter will display the message LOCKED when the Menu button is pressed Press the Enter button while the message is being displayed and enter the correct password to gain access to the menu After exi...

Страница 22: ...played will reset that value to the current display value Press the DISPLAY button a third time and the meter will display LOOP MA on the lower display followed by the measured input current in millia...

Страница 23: ...nostics menu and consult the recommendations described below Troubleshooting Tips Symptom Check Action No display or faint display Check input signal connections Perform hard reset by shorting S and S...

Страница 24: ...selection or increment digit Cycle through maximum minimum and mA display mode ENTER Accept selection value and move to next selection Acknowledge alarms To enter the Advanced Features Menu hold the M...

Страница 25: ...8 655 8990 www predig com LIM6801_I SFT087 Ver 1 300 up 02 22 Contact Precision Digital Technical Support Call 800 610 5239 or 508 655 7300 Fax 508 655 8990 Email support predig com Sales Support Call...

Отзывы: