PRECISION DIGITAL PD233 Скачать руководство пользователя страница 4

– 13 –

PRESURE RANGES:

Compound

Bar/

Compound

psi

(psi)

kPa

KSC

(bar)

vac.

15# & vac.

–100/0

1

–1 to 0

5

30# & vac.

25

1.6

–1 to 1

10

60# & vac.

40

2.5

–1 to 2

15

100# & vac.

6

60

4

–1 to 3

30

100

6

–1 to 30

60

160

10

100

250

16

160

400

25

200

600

40

300

1000

60

500

100

600

160

800

250

1000

400

1500

500

2000
2500
3000
5000
7000

mBar/

Absolute

Temp.

mmH

2

O

MPa

cmH

2

O

(psia)

Options

3000

1

250

15

4°C

5000

1.6

300

25

20°C

10,000

2.5

400

50

60°F

6

500

10

600

40

1000
1600
2000

(2)

2500

(1)

4000
5000
6000

10,000

– 4 –

Bargraph

% of full scale

Flashing display when unit 

pressured below zero

Press to indicate minimum 

or maximum pressure 

gauge has measured

Press again to return to

pressure units

While in max or min mode,

press to clear minimum or

maximum displayed values

UNITS (Pressure)

ENGLISH

PSI

INHG

INH2O

with Temperature

(Options: 60°F,

4°C, 20°C)

FTSW

METRIC

BAR

MBAR

KPA

MPA

mmHG

CMH2O

mmH2O

KG/CM2

UPDATE RATE

(Pressure measurement 

per second)

10x*

5x

2x

1x

BACKLIGHT

(Off options)

ON/OFF*

10 SEC

30 SEC

1 MIN

5 MIN

LANGUAGE(s)

English*

French

Spanish
German

Italian

Portuguese

Dutch

DAMPING

(averages gauge reading

None*

AVG 2
AVG 4
AVG 6
AVG 8

.66˝ high display, 5 digit

QUICK REFERENCE

Содержание PD233

Страница 1: ...elow Pipe to which gauge is attached must be properly grounded 4 00 1 860 17 Battery Installation and Replacement The gauge comes standard with a quantity of three AAA alkaline batteries installed Use either Duracell MN2400 MX2400 or Energizer E92BP X92RP AAA alkaline non rechargeable batteries Batteries have a life of approximately 1000 hours Battery life is dependent on gauge usage backlite sett...

Страница 2: ...er Nylon Protective Carrying Pouch Display Description Flashing Gauge over underpressured 0 or 100 beyond 105 of range LOW BAT Low battery replace ERROR Internal error call customer service 203 378 8281 Pressure unit conversion exceeds RES ERROR display resolution or gauge pressured beyond resolution SPECIFICATIONS WARNING AND ERROR MESSAGES 2 Congratulations on your purchase of the Precision Digi...

Страница 3: ...F Dial Size 3 Case Material 300 Series SS Case Finish Electropolished Case Enclosure Rating Weatherproof IP65 Socket Material 316 SS Socket Size 1 4 NPT Male others on application Socket Location Lower connection 6 00 o clock Ranges Vac thru 7000 psi see other engineering units below for other units of measurement Operating Temperature 0 150 F Storage Temperature 40 180 F DISPLAY Type LCD Display ...

Страница 4: ... 000 4 Bargraph of full scale Flashing display when unit pressured below zero Press to indicate minimum or maximum pressure gauge has measured Press again to return to pressure units While in max or min mode press to clear minimum or maximum displayed values UNITS Pressure ENGLISH PSI INHG INH2O with Temperature Options 60 F 4 C 20 C FTSW METRIC BAR MBAR KPA MPA mmHG CMH2O mmH2O KG CM2 UPDATE RATE...

Страница 5: ...elect the desired option Step 5 Press ENTER to finalize the selection Notes Selecting the DISAB feature does not disable the CLEAR button on the keypad for the MAX MIN fea ture If the DISAB feature is selected pressing the ZERO button on the keypad will cause the display to read DISAB for two seconds The gauge will then revert back to the unit of measure of the gauge The DISAB feature disables the...

Страница 6: ... default and means the unit can be rezeroed between 5 of span If DISAB is selected the zero button is deactivated and no display change will occur when the zero button is pushed Step 1 Press the CONFIG key until the word ZERO SP appears Step 2 Press ENTER 6 Turns the gauge on and off When pressing the ON OFF key while in the off position gauge start up display first indicates the software version ...

Страница 7: ...e the gauge will turn itself off after no activity Indicates default 10 Step 1 Press the CONFIG key until the word CAL IBRAT appears Step 2 Press the ENTER key Step 3 The letters asterisks PW appear Step 4 Press the CONFIG key An Ø appears in the first position Step 5 Press the ENTER key once Step 6 Press the CONFIG key until Ø appears Ø will appear in the second position Step 7 Press ENTER Step 8...

Страница 8: ...lt password that allows access to gauge calibration To access the factory default password KEYPAD FUNCTIONS Indicates default Indicates default 8 Offerings are Never 2 5 15 or 30 minutes To use the AUTO OFF option Step 1 Press the CONFIG key until the word AUTO OFF appears Step 2 Press the ENTER key Step 3 Press the CONFIG key to select the desired AUTO OFF rate Step 4 Press the ENTER key to final...

Отзывы: