P
RO
V
U
™ PD6363 Dual Analog Input Rate/Totalizer
Instruction Manual
22
Display Functions & Messages
The meter displays various functions and messages
during setup, programming, and operation. The
following table shows the main menu functions and
messages in the order they appear in the menu.
Display Functions & Messages
Display
Parameter
Action/Setting
Description
setup
Setup
Enter
Setup
menu
Input
Input
Enter
Input
selection
menu
Ch-A
*
Input
Set input operation for
channel A (*or B)
total
Total
Enable/disable totalizer
functions
YES
Yes
Enable totalizer functions
No
No
Disable totalizer functions
nmode
Mode
Select dual-input
operation mode
Dual
Dual
Set independent dual
input mode
ud AB
Up/Down
AB
Set channel A total
add/subtract based on the
state of channel B
ud A1
Up/Down
AI
Set channel A total
add/subtract based on the
state of a digital input
ud b1
Up/Down
BI
Set channel B total
add/subtract based on the
state of a digital input
ud b1
Up/Down
ABI
Set channel A & B total
add/subtract based on the
state of a digital input for
each
Quad 1
Quadrature
1
Set type 1 quadrature
operation
Quad 2
Quadrature
2
Set type 2 quadrature
operation
Quad 4
Quadrature
4
Set type 4 quadrature
operation
units
Unit
Select the display
units/tags
Ch-A
*
Rate unit
Set rate unit or tag for
channel A (*or B)
Ch-C
Math unit
Set unit or tag for math
channel C
Tot-A
*
Total unit
Set total unit or tag for
channel A (*or B)
Gtot-A
*
Grand total
unit
Set grand total unit or tag
for channel A (*or B)
Dec pt
Decimal
point
Set decimal point
Ch-A
*
Decimal
point
Set decimal point for
channel A (*or B or C)
Rate
*
Rate
Set rate decimal point
(*channel A and B only)
Display Functions & Messages
Display
Parameter
Action/Setting
Description
Total
*
Total
Set total decimal point
(*channel A and B only)
Gtotal
*
Grand total
Set grand total decimal
point (*channel A and B
only)
prog
Program
Enter the
Program
menu
InCAL
Input
calibration
Enter the
Input Calibration
menu
Ch-A
Channel A
Enter channel A input
setup
Fact-a
K-factor A
Enter channel A k-factor
SCal-a
Scale A
Enter the
Scale
menu for
channel A
Cal-A
Calibrate A
Enter the
Calibration
menu for channel A
Inp 1
Input 1
Calibrate input 1 signal or
program input 1 value
Dis 1
Display 1
Program display 1 value
Inp 2
Input 2
Calibrate input 2 signal or
program input 2 value
(up to 32 points)
Dis 2
Display 2
Program display 2 value
(up to 32 points)
Error
Error
Error, calibration or scaling
not successful, check
signal or programmed
value
Ch-b
Channel B
Enter channel B input
setup
Fact-b
K-factor B
Enter channel B k-factor
SCal-b
Scale B
Enter the
Scale
menu for
channel B
Cal-b
Calibrate B
Enter the
Calibration
menu for channel B
tsetup
Total setup
Enter the
Total Setup
menu
Ch-A
*
Channel A
Setup the total for channel
A (*or B)
tbase
Time base
Program total time base
T Cf
Total
conversion
factor
Program total conversion
factor
Gt CF
Grand total
conversion
factor
Program grand total
conversion factor
treset
Total reset
Program total reset mode:
auto or manual
Ch-A
*
Channel A
Set total reset modes for
channel A (*or B)
T rst
Total reset
Program total reset mode:
auto or manual
Gt rst
Grand total
reset
Program grand total reset
mode: auto or manual