ProtEX-MAX PD8-6200 Explosion-Proof Analog Input Rate/Totalizer Instruction Manual
26
Display
Parameter Action/Setting
Lt-CLr
Latching-
cleared
Set relay for latching
operation with manual
reset only after alarm
condition has cleared
(relays assigned to rate)
Altern
Alternate
Set relay for pump
alternation control (relays
assigned to rate)
Sanmpl
Sampling
Set relay for sampling
operation
OFF
Off
Disable relay and front
panel status LED
(Select Off to enable
Interlock feature)
Set 1
Set 1
Program set point 1
RSt 1
Reset 1
Program reset point 1
RLY 2
Relay 2
Relays 2-4 setup
FaiLSF
Fail-safe
Enter
Fail-safe
menu
FLS 1
Fail-safe 1
Set relay 1 fail-safe
operation
on
On
Enable fail-safe operation
off
Fail-safe
off
Disable fail-safe operation
DeLAY
Delay
Enter relay
Time Delay
menu
DLY 1
Delay 1
Enter relay 1 time delay
setup
On 1
On
Set relay 1 On time delay
OFF 1
Off
Set relay 1 Off time delay
break
Loop break
Set relay condition if loop
break detected
(For mA input only)
iGnorE
Ignore
Ignore loop break
condition
(Processed as a low signal
condition)
On
On
Relay goes to alarm
condition when loop break
is detected
OFF
Off
Relay goes to non-alarm
condition when loop break
is detected
Aout
Analog
output
Enter the
Analog output
scaling menu
Dis 1
Display 1
Program display 1 value
Out 1
Output 1
Program output 1 value
(e.g. 4.000 mA)
Display
Parameter Action/Setting
Dis 2
Display 2
Program display 2 value
Out 2
Output 2
Program output 2 value
(e.g. 20.000 mA)
reset
Reset
Press Enter to access the
Reset
menu
Rst Gt
Reset
grand total
Press Enter to reset grand
total
Rst Hi
Reset high
Press Enter to reset max
display
Rst Lo
Reset low
Press Enter to reset min
display
Rst HL
Reset
high & low
Press Enter to reset max &
min displays
Rst t
Reset total
Press Enter to reset total
Rst tr
Reset tare
Reset tare (Used when
Total
is
no
only)
Contrl
Control
Enter
Control
menu
Auto
Automatic
Press Enter to set relays
and analog output for
automatic operation
mAn
Manual
Press Enter to manually
control relays or analog
output operation
pass
Password
Enter the
Password
menu
Pass 1
Password
1
Set or enter Password 1
Pass 2
Password
2
Set or enter Password 2
Pass 3
Password
3
Set or enter Password 3
Total
Total
password
Set or enter password for
manual reset
Gtotal
Grand total
password
Set or enter password for
manual reset
nonrst
Non-
resettable
Non-resettable grand total
set after entering “050873”
for Gtotal password
unloc
Unlocked
Program password to lock
meter
locd
Locked
Enter password to unlock
meter
999999
-99999
Flashing
display
Overrange condition
Underrange condition