PD6600 Series Loop-Powered Process Meters
Instruction Manual
9
PDA2360 Plastic Control Stations
Model
Description
Emergency Button
Ack Button
Blank Button
Reset Button
Tare Button
Stop Button
Silence Button
Notes:
1. These control stations do not carry hazardous area approvals
and are thus not suitable for location in hazardous areas. The
use of additional protective devices may allow them to be
installed in a safe area and connected to a device in a hazardous
area. User should consult a professional engineer to determine
suitability of these products for their specific application.
2.
Control stations can be connected directly to the meter’s Digital
Input terminals labeled DI+ and DI-. See
for details.
Light / Horn & Button Accessories
Model
Description
Red Light / Horn and Reset Button
with Holes Drilled in Enclosure
(1)
Green Light / Horn and Reset
Button with Holes Drilled in
Enclosure
(1)
Yellow Light / Horn and Reset
Button with Holes Drilled in
Enclosure
(1)
Blue Light / Horn and Reset Button
with Holes Drilled in Enclosure
(1)
White Light / Horn and Reset Button
with Holes Drilled in Enclosure
(1)
Note:
1. This MOD supplies the Light / Horn and Reset Button. The
enclosure comes pre-drilled with holes for Light / Horn and Reset
Button and the user performs the installation and wiring. Meter and
enclosure are sold separately. The Light / Horn hole is in the back
left corner of the enclosure and the Reset Button is centered on the
cover of the enclosure below the meter about an inch off the
bottom of the cover except on the PDA3400 series where it is
mounted on the side of the enclosure.
Signal Splitter & Conditioner Accessories
Model
Description
Signal Isolator with One 4-20 mA
Input and One 4-20 mA Output
Signal Splitter with One 4-20 mA
Input and Two 4-20 mA Outputs
Signal Conditioner with One 0-10
VDC Input and One 4-20 mA Output
Signal Conditioner with One
4-20 mA Input and One 0-10 VDC
Output
Note:
These signal splitters and conditioners do not carry hazardous area
approvals and are thus not suitable for location in hazardous areas.
The use of additional protective devices may allow them to be in-
stalled in a safe area and connected to a device in a hazardous area.
User should consult a professional engineer to determine suitability of
these products for their specific application.
PDA6420 Split Core AC Current
Transducer
Model
Description
Input: 30/60/120 AAC;
Output: 4-20 mA
Note:
These split core transducers do not carry hazardous area approvals
and are thus not suitable for location in hazardous areas. The use of
additional protective devices may allow them to be installed in a safe
area and connected to a device in a hazardous area. User should
consult a professional engineer to determine suitability of these prod-
ucts for their specific application.
Each Light / Horn accessory comes with
9 labels for the button.