background image

INSTRUCTION MANUAL

PA602 | PA604 | PA500D

Amplifier Settings

Gain Calibration

The gain control (input sensitivity) on this amp is not a volume control. It is designed to provide proper match-
ing of various source units to this amplifier, and provides a reference to how much signal will be necessary to
reach maximum operating power. Correct settings will ensure safe operation for both your amplifier and
speakers.

• Start by turning the gain level to the “MAX” setting. This is the minimum level, far right.
•Next, turn up your head unit volume up to 75% of max volume. For example, if your digital volume control

goes to “50”, you would use the “40” level for this exercise.

•Last, slowly begin increasing the gain sensitivity ‘counter-clockwise until distortion becomes audible, and

then turn the gain back a notch. You have now properly set your input sensitivity.

Crossover Control

Your amplifier has been designed with an onboard crossover, or filter management system. How you configure
these settings will be dependent on the speakers you are connecting to the amplifier. The crossover circuit con-
sists of two main settings: 1. Filter Type; 2. Frequency Adjustment.

The “filter type” is controlled by a “LPF, FULL, HPF” switch. The low-pass filter, LPF, will allow only low fre-
quency information to pass on to the speakers. The opposite would be achieved using the HPF, high pass filter.
When no filter is required, the FULL setting would be selected, allowing all frequencies to pass.

For proper operation of some speakers, it is necessary to select the crossover point to which they will play. The
“frequency adjustment” setting allows you to accomplish this. In a LPF mode, only frequencies up to the
crossover point will play, with a gentle roll-off beyond that point. In HPF mode, any frequency above that point
will be heard, with those below being filtered away gradually.

Low Level Output

Rather than running a 2nd RCA for multiple amplifiers, the low level output offered on the PA602 will provide a
full-range signal to an additional amplifier. Simply run a shorter RCA from this amplifier to the next one in line, 
such as your PA500D subwoofer amplifier. Fading capability will not be possible in this arrangement.

Subsonic Filter

Getting the most out of your amplifier is our goal. Having a subsonic filter in your subwoofer amplifier is going
to achieve just that. If you’re running a ported subwoofer system, it’s crucial that the output signal from your
amplifier doesn’t drop drastically below the tuning frequency. If that should happen, your subwoofer will feel as
if it’s in open air. The result, slow and permanent damage to the voice coil.

The subsonic filter found on our PA500D offers a continuously variable setting from of 10Hz to 50Hz. This will
ensure that sub-harmonics are dropped off quickly from your desired frequency. Proper setting of this filter will
help your subwoofer play cleaner, louder and with less distortion. Furthermore, your amplifier runs more effi-
ciently by not wasting voltage and current on reproducing unwanted or damaging frequencies.

Содержание PA500D

Страница 1: ...INSTRUCTION MANUAL LIVERT D INSTRUCTIONS AMPLIFIERS AMPLIFICATEURS PA602 PA604 PA500D...

Страница 2: ...d to your speakers and subwoofers Stability is essential in delivering a clean output signal especially when your speaker system drops below normal impedance levels Our dynamic full range Class AB amp...

Страница 3: ...ion Circuitry Short Voltage Overload and Thermal Protection Indicator PA602 PA604 PA500D Features PA500D Class D Circuitry 2 ohm stable Surface Mount Technology MOSFET Power Supply Dual Amplifier Summ...

Страница 4: ...ne the fuse size required under the hood Your amplifier should turn on only when ignition is activated This can be accomplished by connecting an 18 gauge wire to the trigger output on your head unit I...

Страница 5: ...allowing all frequencies to pass For proper operation of some speakers it is necessary to select the crossover point to which they will play The frequency adjustment setting allows you to accomplish...

Страница 6: ...in this manual for a configuration diagram Protection Circuitry This amplifier has been outfitted with protection circuitry against short overload low voltage and thermal shut down In a functional st...

Страница 7: ...THD 0 03 0 03 0 08 Signal to Noise Ratio 90db 90db 80db Frequency Response 10 25KHz 10 25KHz 10 180Hz Crossover HPF FULL LPF HPF FULL LPF LPF High Pass HPF 50 750Hz 50 750Hz n a Low Pass LPF 50 750Hz...

Страница 8: ...INSTRUCTION MANUAL PA602 PA604 PA500D Installation Signal Input...

Страница 9: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA602 Wiring Configuration Note Use a minimum of 8ga power and ground on this amplifier...

Страница 10: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA604 Wiring Configuration Note Use a minimum of 8ga power and ground on this amplifier...

Страница 11: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA500D Wiring Configuration Note Use a minimum of 4ga power and ground on this amplifier A 40 amp fuse is required...

Страница 12: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA500D Master Slave Configuration Note Use a minimum of 4ga power and ground on this amplifier A 80 amp fuse is required...

Страница 13: ...ielle pour offrir un signal de sortie propre plus sp cialement lorsque vos haut parleurs tombent sous le seuil de leur niveau d imp dance normale Nos dynamiques amplificateurs plein registre de Classe...

Страница 14: ...tection quadruple court circuit tension surcharge et thermique T moin de protection PA602 PA604 PA500D Features PA500D Technologie de montage en surface des composantes Alimentation par MOSFET Amplifi...

Страница 15: ...ur devrait se mettre sous tension seulement lorsque vous tournez la cl de contact Ceci peut tre accompli en reliant un fil de calibre 18 la sortie de d clenchement de l unit principale Si vous utilise...

Страница 16: ...r obtenir un bon rendement de certains haut parleurs il est n cessaire de s lectionner le point d aiguillage qui leur convienne Le r glage de la fr quence d ajustement vous permet d accomplir cette op...

Страница 17: ...tection Cet amplificateur est muni d un circuit de protection contre les courts circuits les basses tensions la surcharge et les arr ts par d tection thermique En mode de fonctionnement normal la DEL...

Страница 18: ...08 Rapport signal bruit 90db 90db 80db R ponse en fr quences 10 25KHz 10 25KHz 10 180Hz Aiguillage HPF FULL LPF HPF FULL LPF LPF High Pass HPF 50 750Hz 50 750Hz n a Low Pass LPF 50 750Hz 50 750Hz 40...

Страница 19: ...MANUEL DE L UTILISATEUR PA602 PA604 PA500D Installation Entr e du signal Unit source Unit source Unit source...

Страница 20: ...UTILISATEUR PA602 PA604 PA500D PA602 Configuration du c blage Configuration 2 canaux Configuration en mode pont Remarque Utilisez un fil de calibre 8 pour l alimentation et la mise la masse pour cet a...

Страница 21: ...TILISATEUR PA602 PA604 PA500D PA604 Configuration du c blage Remarque Utilisez un fil de calibre 8 pour l alimentation et la mise la masse pour cet amplificateur Configuration en 4 canaux Configuratio...

Страница 22: ...L UTILISATEUR PA602 PA604 PA500D PA500D Configuration du c blage Remarque Utilisez un fil de calibre 4 pour l alimentation et la mise la masse de cet amplificateur Un fusible de calibre 40 amp res es...

Страница 23: ...UTILISATEUR PA602 PA604 PA500D PA500D Configuration Maitre Esclave Remarque Utilisez un fil de calibre 4 pour l alimentation et la mise la masse de cet amplificateur Un fusible de calibre 80 amp res...

Страница 24: ...21000 TransCanada Baie D Urf Qu bec H9X 4B7 Tel 514 457 2555 Fax 514 457 0055 Visit us www precision acoustics com...

Отзывы: