Features 

PA602, PA604

• Class AB Circuitry - 2 ohm stable
• Surface Mount Technology
• MOSFET Power Supply
• Frequency response from 10Hz to 25KHz
• Low Level Input – variable up to 5 volts RMS
• Gold Plated Input & Output Terminals
• Tri-mode Crossover Selection - LPF / FULL / HPF
• Variable Crossover Control from 50 to 750Hz
• Quad Protection Circuitry - Short, Voltage, Overload and Thermal
• Protection Indicator

PA602

PA604

PA500D

Features 

PA500D

• Class D Circuitry – 2 ohm stable
• Surface Mount Technology
• MOSFET Power Supply
• Dual Amplifier Summing – master/slave
• Gold Plated RCA Connections
• Variable Low Pass Filter Control from 40-180Hz @ 18dB/oct
• Subsonic Filter from 10 to 50Hz
• Frequency response from  10 to 180Hz
• Low Level Input – variable up to 5 volts RMS
• Heavy Duty Terminal Block for Power Input & Speaker Output
• Quad Protection Circuitry - Short, Voltage, Overload and Thermal
• Protection Indicator

Содержание PA500D

Страница 1: ...INSTRUCTION MANUAL LIVERT D INSTRUCTIONS AMPLIFIERS AMPLIFICATEURS PA602 PA604 PA500D...

Страница 2: ...d to your speakers and subwoofers Stability is essential in delivering a clean output signal especially when your speaker system drops below normal impedance levels Our dynamic full range Class AB amp...

Страница 3: ...ion Circuitry Short Voltage Overload and Thermal Protection Indicator PA602 PA604 PA500D Features PA500D Class D Circuitry 2 ohm stable Surface Mount Technology MOSFET Power Supply Dual Amplifier Summ...

Страница 4: ...ne the fuse size required under the hood Your amplifier should turn on only when ignition is activated This can be accomplished by connecting an 18 gauge wire to the trigger output on your head unit I...

Страница 5: ...allowing all frequencies to pass For proper operation of some speakers it is necessary to select the crossover point to which they will play The frequency adjustment setting allows you to accomplish...

Страница 6: ...in this manual for a configuration diagram Protection Circuitry This amplifier has been outfitted with protection circuitry against short overload low voltage and thermal shut down In a functional st...

Страница 7: ...THD 0 03 0 03 0 08 Signal to Noise Ratio 90db 90db 80db Frequency Response 10 25KHz 10 25KHz 10 180Hz Crossover HPF FULL LPF HPF FULL LPF LPF High Pass HPF 50 750Hz 50 750Hz n a Low Pass LPF 50 750Hz...

Страница 8: ...INSTRUCTION MANUAL PA602 PA604 PA500D Installation Signal Input...

Страница 9: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA602 Wiring Configuration Note Use a minimum of 8ga power and ground on this amplifier...

Страница 10: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA604 Wiring Configuration Note Use a minimum of 8ga power and ground on this amplifier...

Страница 11: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA500D Wiring Configuration Note Use a minimum of 4ga power and ground on this amplifier A 40 amp fuse is required...

Страница 12: ...INSTRUCTION MANUAL PA602 PA604 PA500D PA500D Master Slave Configuration Note Use a minimum of 4ga power and ground on this amplifier A 80 amp fuse is required...

Страница 13: ...ielle pour offrir un signal de sortie propre plus sp cialement lorsque vos haut parleurs tombent sous le seuil de leur niveau d imp dance normale Nos dynamiques amplificateurs plein registre de Classe...

Страница 14: ...tection quadruple court circuit tension surcharge et thermique T moin de protection PA602 PA604 PA500D Features PA500D Technologie de montage en surface des composantes Alimentation par MOSFET Amplifi...

Страница 15: ...ur devrait se mettre sous tension seulement lorsque vous tournez la cl de contact Ceci peut tre accompli en reliant un fil de calibre 18 la sortie de d clenchement de l unit principale Si vous utilise...

Страница 16: ...r obtenir un bon rendement de certains haut parleurs il est n cessaire de s lectionner le point d aiguillage qui leur convienne Le r glage de la fr quence d ajustement vous permet d accomplir cette op...

Страница 17: ...tection Cet amplificateur est muni d un circuit de protection contre les courts circuits les basses tensions la surcharge et les arr ts par d tection thermique En mode de fonctionnement normal la DEL...

Страница 18: ...08 Rapport signal bruit 90db 90db 80db R ponse en fr quences 10 25KHz 10 25KHz 10 180Hz Aiguillage HPF FULL LPF HPF FULL LPF LPF High Pass HPF 50 750Hz 50 750Hz n a Low Pass LPF 50 750Hz 50 750Hz 40...

Страница 19: ...MANUEL DE L UTILISATEUR PA602 PA604 PA500D Installation Entr e du signal Unit source Unit source Unit source...

Страница 20: ...UTILISATEUR PA602 PA604 PA500D PA602 Configuration du c blage Configuration 2 canaux Configuration en mode pont Remarque Utilisez un fil de calibre 8 pour l alimentation et la mise la masse pour cet a...

Страница 21: ...TILISATEUR PA602 PA604 PA500D PA604 Configuration du c blage Remarque Utilisez un fil de calibre 8 pour l alimentation et la mise la masse pour cet amplificateur Configuration en 4 canaux Configuratio...

Страница 22: ...L UTILISATEUR PA602 PA604 PA500D PA500D Configuration du c blage Remarque Utilisez un fil de calibre 4 pour l alimentation et la mise la masse de cet amplificateur Un fusible de calibre 40 amp res es...

Страница 23: ...UTILISATEUR PA602 PA604 PA500D PA500D Configuration Maitre Esclave Remarque Utilisez un fil de calibre 4 pour l alimentation et la mise la masse de cet amplificateur Un fusible de calibre 80 amp res...

Страница 24: ...21000 TransCanada Baie D Urf Qu bec H9X 4B7 Tel 514 457 2555 Fax 514 457 0055 Visit us www precision acoustics com...

Отзывы: