Chapter 3 Operation 

3.1 Receiver 

Receiver Modes 

The receiver can be operated in one 

of four different modes.  
 

 

In Shield Level mode the receiver 
can be used to measure the amount 

of attenuation/shield level that is 

provided by an enclosure or other 
obstacles between the transmitter 

and receiver.  Before a shield level 

test is conducted, the receiver is 
initialized with the transmitter to 

read 0dB shield level. 

 

In Signal Strength mode the receiver can be 

used to measure the signal level of a 
continuous wave signal.  The receiver has a 

narrow (+/-7.5 kHz) IF bandwidth 

enabling it to measure  a test signal in 
the presence of interfering signals in 

the same band.  Although the 

receiver has no demodulation 
capabilities, it can be used to measure 

the signal level of narrow band 

modulated signals. 

 

In Spectrum Monitor mode the 

receiver can be used to view a 12 MHz 

span of the frequency spectrum.  This 
mode is ideal for locating a clear 

frequency that you can use for 

conducting a test or for identifying 
large interfering signals that could 

cause errors in measurements.  

 

Page 7 

 

Spectrum Monitor Mode

 

 

 

Shield Level Mode

 

Содержание PAMS

Страница 1: ...User s Manual The solution for making easy shielding effectiveness measurements PAMS Portable Attenuation Measurement System 310 010042 001...

Страница 2: ...cts in material and workmanship under use as specified in this guide for a period of one year from date of delivery PRAXSYM further agrees to repair or replace at its discretion any failure which upon...

Страница 3: ...readout display the shielding level dB Separately the transmitter and receiver will also work well in custom applications The transmitter provides a portable and semi rugged CW transmitter with adjus...

Страница 4: ...e at Power Jack DC 15 1 0 V 2A Battery Operation 4 hours operation 70 minutes charge Controls OFF VOL MODE CAL FREQUENCY SELECT T HOLD UP DOWN LOCK BACK LIGHT Indicators MODE CAL STATUS SIGNAL LEVEL F...

Страница 5: ...o 60 dBm 1 2 or 5 dB steps Frequency Stability 2 5 ppm Charge Voltage at Power Jack DC 15 1 0 V 2A Battery Operation 2 hours operation 70 minutes charge Controls OFF ON MODE ATTEN FREQUENCY SELECT BAC...

Страница 6: ...may self discharge to less than 3 Volts after a period of storage or if the unit is left on for several days During a new charge cycle it will first enter a pre charge trickle state before beginning t...

Страница 7: ...ood practice to disconnect the batteries to ensure long battery life With the batteries disconnected they can be stored charged or discharged To disconnect the batteries unplug the 2 pin connector usi...

Страница 8: ...used to measure the signal level of a continuous wave signal The receiver has a narrow 7 5 kHz IF bandwidth enabling it to measure a test signal in the presence of interfering signals in the same band...

Страница 9: ...eps Depress the F DIGIT switch to toggle the step size between 1 MHz and 100 kHz The current step size is displayed on the FR ADJ line of the display The frequency can be set in either Signal Strength...

Страница 10: ...Although the screen will have lower visibility by turning the backlight off the battery life will be increased by approximately 10 Control Lock Once set the controls of the receiver can be locked to...

Страница 11: ...de the output level of the CW signal can be changed using the frequency control knob Depressing the mode button a second time places the transmitter in broadband mode See Section 3 4 for a description...

Страница 12: ...test frequency to ensure no interfering signal is present on your test frequency When making measurements in an unfamiliar area set the receiver to Spectrum Monitor mode to determine frequencies in t...

Страница 13: ...receiver will flash INITIALIZE PRESS CAL on the display Ensure that there are no obstructions between the transmitter and receiver and then depress the CAL button on the Receiver The display should i...

Страница 14: ...he enclosure open measure the level of the pickets with a spectrum analyzer Shield level can be determined by calculating the drop in picket level after the enclosure door is closed 3 5 Monitor Mode O...

Страница 15: ...er On Rotate POWER switch to the ON position Depress the mode button until the LCD mode line reads monitor NOTE The INITIALIZE PRESS CAL warning will flash until a system level calibration is performe...

Страница 16: ...15 SHIELDED ROOM Close Door Begin Test in MONITOR mode Set the switch matrix to select ANT 1 Read and manually record the MONIT LEVEL dB Repeat the above sequence for antennas 2 12 12 Position RF Swi...

Страница 17: ...the threshold a variable tone is emitted Low frequency tones correspond to low poor shielding levels while high frequency tones signify high better shielding levels If the shielding level exceeds the...

Страница 18: ...Page 17 Notes...

Страница 19: ...Notes Page 18 P R A X S Y M...

Страница 20: ...900 000001 001 Rev G P R A X S Y M...

Отзывы: