2.3 Scan Mode
Each channel, 1 and 2, can be independently set to
Scan Mode
. In
Scan Mode
, the transmitter cycles through the
Setups
at an adjustable
scan rate. The
Scan Mode
configurations are accessed through the
Channel 1 Setup
and
Channel 2 Setup
options in the
Main Menu
.
Selecting
Scan Setup
from the
Channel 1 Setup
menu portion displays
the various configurations associated with
Scan Mode
on channel 1,
likewise for channel 2.
Using the up/down arrows and
SEL (Select)
key will modify the scan settings
.
Selecting
Scan Order
allows the user
to choose which
Setups
will be used in the scan (AB, ABC, ABCD).
Selecting
Dwell Time
allows the user to select the duration at which
each
Setup
will be enabled. Selecting
Scan Armed
prepares the
transmitter to begin the
Scan
. The
Scan
, RF Output, will not be
enabled until
Scan ON/OFF
is pressed on the main screen. The Zero
key will also start the
Scan
.
Selecting The
Scan Setup
option available
in the
channel 1
Setup
menu,
modifies the
Scan
settings
The
Scan Setup
configurations
are available in
the
Scan Setup
menu.
After the scan is
armed, touching
SCAN ON-OFF
begins the scan
(enables the RF
output).