Programming / test key 

Dip switch 

Programming / test key 

Dip switch 

The system is intended as safety device for gates and includes a receiver (connected to the control unit) and a maximum of 8  transmitters (4 for each 
of the two relays of the receiver) connected to the sensitive edges. It can work both with the clean NC contact mechanical edges, and with the 8,2K 
edges. The two contacts of the receiver (normally closed with the powered device) are independent and can be connected to the relative input of the 
control unit, put in series to the stop of the control unit, or in series to the photo devices contacts. Two contacts are also present on the receiver to be 
able to carry out the self – test system.  
The transmission of the signals between transmitter and receiver happens on 868 MHz band in bidirectional way. 

The installation and the maintenance of the system must be carried out by qualified personnel. The manufacturer can not be considered 
responsible for any damages caused by an improper, incorrect or irrational use of the product. 
Warning: this device can block the automation if the batteries of the mobile part is flat. 

Transceiver system 

1.  DESCRIPTION 

2.  CONFIGURATION AND ELECTRICAL CONNECTIONS 

NOTE

: The signal given on output (clean contact or 8,2K) to 

the relay 1 and 2 depends on the position of the selection 
output signal jumper. 

2.1  Receiver TCO7RX  

Jumper of selection power supply tension.     
          Right : 12Vac/dc     Left: 24Vac/dc 

Dip switch 

Programming / reset key 

WARNING: if the power supply of the TCO7RX is carried 
out  in  alternating  current  (Vac),  the  power  supply  must 
be  got  through  an  insulation  transformer  (of  security, 
SELV  tensions)  which  has  a  limited  power  or  almost  a 
protection against the short circuit. 

Jumper of selection 
output signal 

Output relay 

0.5A at 42.4Vac 

1A at 30Vdc 

NOTE

:  The  level  of  acoustic  pressure  generated  by  the 

device is less then 70 dBA. 

MECHANICAL 

(N.C) EDGE 

2.3 Transmitter  8,2K resistive edge 

2.2 Transmitter  mechanical edge 

Resistive edge 

Resistance 

8,2K

 

WARNING: 

DIP1 OFF: 

mechanical safety edge  

If you want to connect a NON-resistive 
element (normally closed contact), 
you must set dipswitch 1 on "OFF".  

 
WARNING: this application does not 
comply with the automatic doors security 
norm for use EN 12453 because the 
connection of the non-resistive component 
connected to the transmitter is not checked.

 

WARNING: 
DIP1 ON: 

resistive safety edge 8,2K

 

If  you  want  to  connect  a  resistive  element 
(8k2  resistor),  you  must  set  dipswitch  1  on 
"ON".  

Содержание TCO7RX

Страница 1: ...ive edges TRANSMITTER TCO7TX TCO7RX TCO7TX Notified Body Directive 98 37 EC EC ident N 1844 PRASTEL FRANCE ZI Athélia II 225 Impasse du Serpolet 13704 LA CIOTAT Cedex FRANCE Tel 334 42 98 06 06 Fax 334 42 04 53 51 RECEIVER TCO7RX Bidirectional communication ...

Страница 2: ...flat Transceiver system 1 DESCRIPTION 2 CONFIGURATION AND ELECTRICAL CONNECTIONS NOTE The signal given on output clean contact or 8 2K to the relay 1 and 2 depends on the position of the selection output signal jumper 2 1 Receiver TCO7RX Jumper of selection power supply tension Right 12Vac dc Left 24Vac dc Dip switch Programming reset key WARNING if the power supply of the TCO7RX is carried out in...

Страница 3: ...ip 3 and dip 4 which will have to correspond to the one of the transmitters 5 The inputs are handled in the same way as the photocells test the control unit to carry out the photocells test switches off the power supply of the receiver and check that the relays of the correspondent receiver opens itself In this device the input TEST1 and TEST2 are for testing the security devices see chapter 12 MI...

Страница 4: ...annel has been reached 1 Maximum time up for the memorization of the transmitter 10 second 5 3 Summary of the acoustic signalling during the learning phase Beside the two receiver relays a jumper for the selection of the type signal to give on output is present This signal can be 1 A clean contact open contact in case of alarm and close if the alarm is not present 2 A contact type 8 2K resistance ...

Страница 5: ...r emits one uninterrupted bip N B If one transmitter is in alarm but it necessary to open or close the automation in any case it s necessary to press and keep pressed the programming test button of the indicted transmitter of the indicated and in the same time to move the automation WARNING If the batteries are completely flat it will be necessary to change them The battery life is of about 2 year...

Страница 6: ...e it will be necessary to keep in consideration the condition of dangerous that can be created if the power supply battery is taken off to the transmitter during the interval of time before the successive transmission of its state and successively the sensible edge goes on alarm in this case the receiver will signal the alarm only after the period of interrogation With the dip 2 of the transmitter...

Отзывы: