STARTING THE GENERATOR SET
Before attempting to start the generator set, ensure that
all instructions given in previous sections have been
followed completely.
• Check oil and fuel levels.
• Turn the fuel valve under the fuel tank on.
FUEL SUPPLY SOLENOID SWITCH
• Place the Fuel Supply Solenoid Switch in the UP
position for RECOIL START.
• Place the Fuel Supply Solenoid Switch in the DOWN
position for ELECTRIC START.
RECOIL START
• Turn key to 1st position-
Warning Light On.
• Slowly pull recoil cord until
resistance is felt, and then
pull firmly. Let the recoil
rewind slowly to avoid
damage.
ELECTRIC START
• Turn key to 1st position-
Warning Light On.
• Turn key to 2nd position-
Starting.
• Return key to 1st position when engine is running.
• Note: If the engine does not start after 20 seconds, stop
and wait 1 minute and repeat this step.
PRIMING PROCEDURE
This procedure may be required for the initial start or
subsequent starts, if the fuel runs out, or if air is in the fuel
system.
1. Fill the tank completely with DIESEL fuel.
2. Open the fuel shut-off valve under the tank.
3. Pump the primer lever 2-3 times.
4. Watch for the fuel filter to be completely filled with diesel
with no air inside.
5. Crank the engine by turning the ignition key or pulling
the recoil.
VOLTAGE SELECTOR GUIDE (applicable models)
The voltage selector switch allows the generator set to produce
120 volts only or to produce 120/240 volts simultaneously. With
the switch in the 120V position only the 120V receptacles may
be used. All of the power from the generator is available at 120
volts but the 240V output is not available. In the 120/240V
position all receptacles are operable however only half of the
generator output is available at any one 120V receptacle. Full
power may be pulled from the generator from the 240V
receptacle. The switch should always be left in the 120V
position when 240 volts are not needed. This balances the
load on the generator more effectively.
STOPPING THE GENERATOR SET
Unplug all appliances and let
the engine run unloaded for a
couple of minutes. Turn the key
switch to the Stop (0) position.
Turn the fuel valve on the
bottom of the fuel tank Off.
GENERATOR APPLICATION
WHAT IS A GENERATOR
A generator is basically a prime mover, typically a gasoline or
diesel engine, coupled to an alternator to produce electricity. It
is very useful as a substitute power source during power
outages or as the primary source in remote locations where
power is not available. Generators are essential for people
such as contractors or farmers who are always in need of
portable power. They are also very convenient for recreational
use.
SELECTING A GENERATOR
Selecting the proper generator is important. A generator that is
too small for your application will not run all of the equipment
needed. A generator that is too large will cost more and if
never used to its potential the money is wasted. The correct
size generator is determined by totaling the wattage
requirements of the items to be used simultaneously,
determine additional starting wattage requirements and total
these numbers. Select a generator with a continuous rating
that exceeds this by about 20% to allow for expansion. See the
table in the section titled “Generator Set Overload” for some
wattage guidelines of common equipment.
FUEL VALVE
UP
DOWN
FUEL SUPPLY
SOLENOID
SWITCH
Содержание S5500
Страница 7: ...7 English 0070661 Register your Pramac generator online at www powermate com REGISTER YOUR PRODUCT ...
Страница 18: ...18 0070661 S5500 A C WIRING SCHEMATIC SCHÉMA ÉLECTRIQUE D INSTALLATION DE C A ALAMBRADO ESQUEMATICO DE C A ...
Страница 33: ...0070661 33 Registre su generador de Pramac en línea en www powermate com Español REGISTRE SU PRODUCTO ...