16. Backwash Time
The backwash time is set with the switch S1 on the circut board.
4 backwash times are available.
45 sec.
75 sec.
120 sec.
360 sec.
S1
17. Rinsing Time
The rinsing time is set with the switch S2 on the circuit board.
4 rinsing times are available.
20 sec.
40 sec.
60 sec.
90 sec.
S2
18. Switchpoints Backwash Time
The switchpoints for backwash time are set with switch S3 on the circuit board.
4 switchpoints for backwashing are available.
OFF
3 days
7 days
14 days
S3
18.1 Time of Activation of Backwash Cycle
Example:
Example:
Backwash every Monday 09:15
- Set switch S3 to switchpoint 7 days and turn on the Aquastar at 9:15
(press ‘ON’ button on the keyboard)
In order to alter the time of activation, just press the ‘TEST BUTTON’ on the
keyboard at the wanted activation time.
Change activation from Monday 09:15 to Friday 08:00
- press ‘TEST BUTTON’ at the keyboard on Friday 08:00
ATTENTION! Prior to setting/adjusting the Switchpoints ‘backwashing’ the
valve needs to be on position ‘FILTER’ and the Aquastar has to be turned
off. (See page 9)