8. Designated use
9. Assembly
This is a control unit for a multi-port valve with 6 positions for fully automatic filter
backwashing time controlled. A filter pump connection is activated about 10 sec. after
the respective position is reached. Additional electrical connection for a Praher ball valve
EO510 during the cycle is available.
(Device installation - installation of the valve)
Install the valve in the conduit according to the labelling and the sketch below.
Use OCEAN-adapter unions. Threaded connections should be sealed only with teflon
strip. Although the device works in any position, it should not be mounted actuator down,
if possible.
If the difference in level between system and accumulator exceeds 3 meters, a Praher
check valve S6 should be installed to prevent severe damage to the actuator and the
valve due to excessive pressure and flow.
As the filter medium can be washed out during backwashing and rinsing, we recommend
fitting the drain with a throttle. Otherwise a stuck valve plate can adversely affect the
faultless operation of the Aquastar.
Polluted or grainy filtering media require the use of Praher line strainer S4.
IMPORTANT! During a cycle the filter pump motor
Operating pressure for 6-way backwash valve: ABS 3,5 bar / GFK 6bar
must be shut off!!
ATTENTION! For a safe transport the Aquastar is shipped with the valve beeing on
an ´intermediate´ position for relief of the valve sealing, and is
!
Prior to start-up the drive has to be put to position ‘filter’ by pressing the ‘ON’
switch at the membrane keyboard.
not tight
9.1 Function- and installation diagramm
Pump
from pump
Top
to the filter
Bottom
from filter
Return
to the pool
Waste
to the drain
à
à
à
à
à
21
D
GB
Cleaning of filter medium
(i.e. Sand) after backwash
Pool
Pump
Valve
(to filter)
Filter
Valve
(from filter)
Waste
à
à
à
à
à
VI
RINSE
pump
pool
drain
filter bottom
filter top
I
FILTER
pump
pool
drain
filter bottom
filter top
Filtration of medium
(i.e. Water)
Pool
Pump
Valve
(to filter)
Valve (from
filter)
Pool
à
à
à
à
II
WASTE
pump
pool
drain
filter bottom
filter top
Drainlage of pool with
pump
Pool
Pump
Valve
Drain
à
à
à
IV
BACKWASH
pump
pool
drain
filter bottom
filter top
Cleaning up filter medium
(i.e. Sand) in upstream
(reversed flow in filter)
Pool
Pump
Valve
(from filter)
Filter
Valve (to filter)
Waste
à
à
à
à
à
RECIRCULATE
V
pump
pool
drain
filter bottom
filter top
Recirculation of fluid
without filter (Bypass filter)
Pool
Pump
Valve
Pool
à
à
à
Содержание AquaStar easy 1000
Страница 16: ...Notizen 16 ...
Страница 31: ...Notes 31 D GB ...
Страница 32: ... Praher Kunststofftechnik GmbH BA EV DE 06 07 122 A 90343 ...