background image

 

www.praher-plastics.com

 

 

Copyrights 

This operation manual contains copyright protected information. All rights reserved to  

Praher Plastics Austria GmbH. 

 

This operation manual is designed for use by operating personnel only. Copying,  

reproduction or translation of the present document into other languages in whole or 

in part is subject to express written permission by Praher Plastics Austria GmbH. 

 

 

© 2017 Praher Plastics Austria GmbH 

 

Knowledge of the instructions contained in this operation manual is indispensable for preventing 

failure and ensuring faultless operation of the diaphragm valve pneumatically actuated and its 

superstructural parts. Therefore, it is essential, that the person in charge of operating the 

equipment is familiar with the present documentation 

 

 

Introduction to operation manual 

This operation manual is intended to facilitate familiarization with the diaphragm valve 

pneumatically actuated and its superstructural parts and utilization of the same for the intended 

purpose. 

 

This operation manual contains important information for safe, proper and economical operation 

of the diaphragm valve pneumatically actuated and its superstructural parts. Compliance with 

these instructions will contribute to 

 

 

preventing danger 

 

reducing repair costs and equipment failure, and 

 

increasing the liability and service life of the diaphragm valve pneumatically actuated and its 

superstructural parts 

 

This operation manual supplements the instructions provided by existing accident prevention 

and environmental protection regulations. It must be available at the place of utilization of the 

equipment at any time and must be read by each person intending to use the diaphragm valve 

pneumatically actuated and its superstructural parts. This means 

 

 

operation, including 

 

correction measures in case of faulty operation and 

 

maintenance 

 

In addition to the operation manual and the compulsory accident prevention regulations 

applicable at the place of utilization of the equipment, the generally subject specific technical 

rules must be taken into account.  

 

 

 

 

 

 

 

 

Содержание 4 PVC-U

Страница 1: ......

Страница 2: ...1 www praher plastics com...

Страница 3: ...eumatischen Antrieb INHALT Urheberrecht 4 Vorwort zu Bedienungsanleitung 4 Gew hrleistungs und Haftungsanspr che 5 Arbeitssicherheitshinweise 5 Sicherheitshinweise 6 Restrisiken 7 Allgemein 7 Steuerdr...

Страница 4: ...3 www praher plastics com...

Страница 5: ...Personen bekannt ist Vorwort zu Bedienungsanleitung Diese Bedienungsanleitung soll erleichtern das Membranventil mit pneumatischem Antrieb und dessen Aufbauten kennen zu lernen und seine bestimmungsg...

Страница 6: ...me ist eine Dichtheits und Funktionspr fung durchzuf hren Nach der Druckprobe sind alle im Rohrleitungssystem verbauten berwurfmuttern und Schrauben im drucklosen Zustand nachzuziehen Wir empfehlen ei...

Страница 7: ...r 30mA installiert ist Verwenden Sie das Ger t nur in R umen in denen keine brennbaren Gase und D mpfe vorhanden sein k nnen Nehmen Sie das Ger t nicht sofort in Betrieb wenn es von einem kalten in ei...

Страница 8: ...personen sind hinsichtlich der Restgef hrdung durch elektrischen Strom sowie der korrekten Bedienung zu unterweisen sowie auf die Wirksamkeit der Unterweisung zu kontrollieren 6 3 Gef hrdung durch Str...

Страница 9: ...NO und Steuerdruck DA mit PTFE Membrane Steuerdruck max Betriebsdruck f r Dichtwerkstoff DN d Antriebsgr e bar EPDM FPM PTFE EPDM bar bar 15 20 K 52 NC 5 0 10 10 5 K 62 NC 5 0 10 10 20 25 K 62 NC 5 5...

Страница 10: ...chskantschraube 8 Abdeckkappe 9 O Ring 10 Klebemuffe 11 berwurfmutter Montage Nach der Montage des Antriebes und nach einigen Schaltzyklen ca 20 30 ist es notwendig s mtliche Schrauben im drucklosen Z...

Страница 11: ...uffenanschluss G1 8 oder Schnellsteckverbinder Versorgungsdruck 3 bis 7bar Umgebungstemperatur 10 C bis 50 C Betriebsspannung 24V Version 0 48 V AC DC 230V Version 50 250 V AC DC Schutzart IP65 Anschl...

Страница 12: ...ttom 4 INI Bottom 5 Ventilansteuerung 6 Ventilansteuerung GND Anzeigeelemente LEDs Version mit 2 Leiter Initiatoren obere Endstellung LED Top leuchtet gelb untere Endstellung LED Top leuchtet gelb Die...

Страница 13: ...gef gt Leuchtdioden f r Statusanzeige und Diagnose die Einheit ist um 360 um den Ventilantrieb drehbar Status Position haltend Ventil OFFEN Ventil GESCHLOSSEN Ventil ffnet Ventil schlie t Stellungsreg...

Страница 14: ...und Adapterplatten glasfaserverst rktes Polyamid PA GF Innenteile Zinkdruckguss Edelstahl Acetal POMe Aluminium Dichtung NBR PUR Magnetanker und F hrungsrohr Edelstahl Kurzschlussring Kupfer Elektris...

Страница 15: ...551 Position A2 Funktionsplatte 5 2 Baureihe 551 4 2 O Ringe im Lieferumfang enthalten 5 Abluftdrosseln G1 8 Baureihe 551 f r Anschl sse 3 und 5 6 Adapterplatten 7 1 Bohrung 6 5 mm Baureihe 552 553 f...

Страница 16: ...ikationen Abluftdrossel mit Schalld mpfer Medium Luft oder neutrales Gas gefiltert ge lt oder unge lt Betriebsdruck 0 10bar Temperatur 10 C bis 80 C Anschluss G1 8 11 5 Schalld mpfer Spezifikationen B...

Страница 17: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Страница 18: ......

Страница 19: ...h pneumatic actuator CONTENTS Copyrights 3 Introduction to operation manual 3 Warranty and liability 4 Instructions for safety at work 4 Safety instructions 5 Residual Risk 6 General 6 Control pressur...

Страница 20: ...rstructural parts and utilization of the same for the intended purpose This operation manual contains important information for safe proper and economical operation of the diaphragm valve pneumaticall...

Страница 21: ...out before commissioning After the pressure test all nuts and screws of the entire pipe system must be retightened in a depressurized state We recommend a maintenance service testing of functionality...

Страница 22: ...an earth leakage circuit breaker 30 mA is installed Only use the equipment in dry rooms in which no combustible gasses and vapors are present Do not put the equipment into operation immediately if it...

Страница 23: ...staff must be instructed in regard to the residual danger resulting from electricity and familiarized with correct operation Efficiency of the safety training must be verified 6 3 Hazard generated by...

Страница 24: ...ressure and DA control pressure PTFE diaphragm Drive size Control pressure max operating pressure for sealing material DN d bar EPDM FPM PTFE EPDM bar bar 15 20 K 52 NC 5 0 10 10 5 K 62 NC 5 0 10 10 2...

Страница 25: ...xagon bolt 8 Cap 9 O ring 10 Solvent socket 11 Union nut Assembly All fastening screws have to be tighten up and controlled after mounting the actuator and after operation approx 20 30 cycles when the...

Страница 26: ...push in connector Supply pressure 3 to 7 bar Ambient temperature 10 C to 50 C Voltage ranges 24V Version 0 48 V AC DC 230V Version 50 250 V AC DC Degree of protection IP65 Connection diagram mechanica...

Страница 27: ...INI Top 3 INI Bottom 4 INI Bottom 5 Valve control 6 Valve control GND Display elements LEDs Version with 2 wire proximity switches End pos top LED Top Lights yellow End pos bottom LED Top Lights yell...

Страница 28: ...uded with each valve LED indicators for operating status display and diagnostic functions Unit can be rotated through 360 around the centreline of the valve operator status hold position valve OPEN va...

Страница 29: ...es Glass filed polyamide Internal parts Zamak stainless steel acetal POM aluminium Sealing NBR PUR Core and core tube stainless steel Shading coil Copper Electrical characteristics Coil insulation cla...

Страница 30: ...NC function plate Series 551 in position A2 5 2 function plate Series 551 4 2 O ring seals supplied 5 Exhaust reducers G 1 8 Series 551 or protectors adaptable on orifices 3 and 5Interface plates 6 O...

Страница 31: ...er Specifications Exhaust regulater and silencer Fluid air or inert gas filtered lubricated or not Operating pressure 0 10bar Temperature 10 C to 80 C Connector G1 8 11 5 Silencer Specifications Opera...

Страница 32: ..._________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _...

Страница 33: ..._________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _...

Страница 34: ..._________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _...

Страница 35: ...www praher plastics com 18...

Страница 36: ...cklegung Technische nderungen vorbehalten This document contains no warranties but simply conveys initial information The program is constantly expanding and therefore the versions and types correspon...

Отзывы: