Electrical specifications:
Specifications range:
-20 to +60°C
Common specifications:
Supply voltage universal ............................. 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Internal consumption ..................................
≤
2 W (2 channels)
Max. consumption.......................................
≤
3 W (2 channels)
Fuse ............................................................. 400 mA SB / 250 VAC
Isolation voltage, test / operation ............... 3.75 kVAC / 250 VAC
Signal / noise ratio ...................................... Min. 60 dB (0...100 kHz)
Response time (0...90%, 100...10%) .......... < 25 ms
Calibration temperature............................... 20...28°C
Effect of supply voltage
change (24...250 V) ..................................... < ±10
µA
Accuracy, the greater of general and basic values:
5106
Standard
: A
[EEx ia] II C : B
4…20 mA : B
Single
: A
Double
: B
Type
Version
Input
Output
Channels
Order: 5106
4…20 mA : 2
20...4 mA : 9
Supply
Supply
Current, mA
2-wire transmitter
Output
Output
Basic values
Temperature
coefficient
Basic
accuracy
Input type
mA
≤
±16 µA
≤
±1.6 µA/°C
General values
Temperature
coefficient
Absolute
accuracy
Input type
mA
≤
±0.1% of span
≤
±0.01% of span / °C