![PR 5714 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/pr/5714/5714_manual_1592913010.webp)
8 5714V103-UK
NB! Please order the splash-proof cover seperately. Order No. 8335.
Electrical specifications
Specifications range:
-20°C to +60°C
Common specifications:
Supply voltage, universal ..................................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Consumption
Isolation voltage, test / operation ................... 2.3 kVAC / 250 VAC
Signal- / noise ratio ................................................ Min. 60 dB (0...100 kHz)
Response time (0...90 %, 100...10 %), programmable:
Temperature input .......................................... 1...60 s
Current / voltage input ................................. 0.4...60 s
Calibration temperature ....................................... 20...28°C
Accuracy, the greater of general and basic values:
General values
Input type
Absolute
accuracy
Temperature
coefficient
All
≤
±0.1% of reading
≤
±0.01% of reading / °C
Type
Internal consumption
Max. consumption
5714A
2.2 W
2.5 W
5714B/C
2.7 W
3.0 W
5714D
3.2 W
3.5W
Type
Version
5714
Standard. . . . . . . . . . . . . . . . . . . . . . . : A
2 relays. . . . . . . . . . . . . . . . . . . . . . . . : B
Analogue output . . . . . . . . . . . . . . . : C
Analogue output and 2 relys . . . . : D
Order: 5714