SAFE USAGE OF THE PROJECTOR 

 

When unpacking and before disposing of the carton check there is no transportation damage before using the projector. Should there 
be any damage caused by transportation, consult your dealer and do not use the apparatus. 
 
The projector is for indoor use only, IP20. Use only in dry locations. Keep this device away from rain and moisture, excessive heat, 
humidity and dust. Do not allow contact with water or any other liquids. 

DO NOT mount the projector directly onto inflammable surface

 

 
The projector is only intended for installation, operation and maintenance by qualified personnel. 
 
The projector must be installed in a location with adequate ventilation, at least 50cm from adjacent wall surfaces. Be sure that no 
ventilation slots are blocked. 
 
Do not project the beam onto inflammable surfaces, minimum distance is    5m. 

 5m   

 
Avoid direct exposure to the light from the lamp. The light is harmful to the eye. 
 
Do not attempt to dismantle and/or modify the projector in any way. 
 
Electrical connection must only be carried out by qualified personnel. 
 
Before installation, ensure that the voltage and frequency of power supply match the power requirements of the projector. 
 
It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards. 
 
Do not connect this device to any other types of dimmer apparatus. 
 
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the power-cord come into contact with other cables. 
Only handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 
 
Keep a projector’s optical system clean. Do not touch LED lens with bare hands. 
 
The projector should always be installed with a secondary safety fixing. A safety cord is supplied for this; it should be attached as 
shown in “installing the projector” section.   
 
Shields and lens shall be changed if they have become visibly damaged to such an extent than their effectiveness is impaired, for 
example by cracks or deep scratches. 
 
LED lamps should be replaced if damaged or having reached life limit. 
 
Exterior surface temperatures of the luminaire after 5 minutes operation is55

, when steady state is achieved 70

 
There is no user serviceable parts inside the projector, do not open the housing and never operate the projector with the covers 
removed. 
 

If you have any questions, don’t hesitate to consult your dealer or manufacturer. 

 

 

Always disconnect a projector from the POWER when not in use or before cleaning or any 
maintenance work! 

Содержание XLED 1037 PR-8120

Страница 1: ...contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR L...

Страница 2: ...ge specifications in the course of product improvement The publishers cannot be held responsible for the accuracy of the information herein or any consequence arising from them Every unit is tested co...

Страница 3: ...quirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types o...

Страница 4: ...strong enough to support a weight of each projector WARNING 1 The projectorMUSTbe lifted orcarried by the HANDLES instead of clamps 2 Forsafety the safety cord should afford 10 times of the unit s wei...

Страница 5: ...s digital control signals in protocol DMX512 1990 Connect the controller s output to the first fixture s input and connect the first fixture s output to the second fixture s input and connect the rest...

Страница 6: ...menu one by one TO SET THE DMX STARTADDRESS Each projector must be given a DMX start address so that the correct projector responds to the correct control signals This DMX start address is the channe...

Страница 7: ...t Default OFF OFF ON DMX Mode Default XLR First XLR First XLR Only Wireless Only Wireless First WirelessTo XLR Unlink Wireless YES MasterSlaveSelec Default Slave Slave Master Factory Settings YES Para...

Страница 8: ...5 CH9 Pan Tilt Speeds 0 255 CH10 Hold Time 0 1s 25s Note 1 There is only one Projector to be set as a Master in a signal Cable If Master s functions used Please disable DMX control signal 2 When multi...

Страница 9: ...a 2 Green 000 255 Linear adjustment in Green from light to dark of Area 2 12 Area 3 Green 000 255 Linear adjustment in Green from light to dark of Area 3 8 13 Area 1 Blue 000 255 Linear adjustment in...

Страница 10: ...ion Should these be damaged call a qualified technician before replacement The projector has thermal protection device that will switch off the projector in case of overheating should this occur check...

Страница 11: ...ired The lamp can be started but LED lamps are off and not controlled LED boards not connected properly a qualified technician is needed Aprojector s lamps are on but it doesn t respond to the control...

Страница 12: ...10000K DIMMER 0 100 linearly adjustable STROBE Electronic Strobe 0 25F P S PANANDTILT PAN 0 540 and TILT 0 270 withAuto Position Correction Function LIGHTANGLE BeamAngle 1 2 Maximum 13 52 Light SpotA...

Страница 13: ...S die casting aluminum IP20 WORK ENVIRONMENTTEMPERATURE 20 C 40 C WEIGHT Net weight 12 85Kg GrossWeight 16 9 Kg SIZE LIGHTOUTPUT 2m 6m 7m 5m 3m 1m 4m 0m 2m 4m 1m 3m 5m 6m 7m 8m 8m DISTANCE m 27 DIAMET...

Страница 14: ...14 16...

Страница 15: ...30020113 2 Belt 290151352 1 HTD447 3M 8MM Wide Belt 290151353 1 HTD342 3M 8MM Wide First Lens 070070052 37 Second Lens 070070053 37 Stepper Motors 030040162 4 20DAM10D2B K Portescap Stepper Motors 030...

Страница 16: ...16 16 PR LIGHTING LTD 1582 XingyeAvenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 FAX 86 20 3995 2330 P N 320020108A Version 20140108...

Отзывы: