Overholdte myndighedskrav: Standard:
EMC 89/336/EØF, Emission ....................... EN 50 081-1, EN 50 081-2
Immunitet ...................... EN 50 082-2, EN 50 082-1
Emission og immunitet...................... EN 61 326
LVD 73/23/EØF............................................ EN 61 010-1
PELV/SELV................................................... IEC 364-4-41 og EN 60 742
ATEX 94/9/EF .............................................. EN 50 014 og EN 50 020
11
Indgange:
Følertyper:
NAMUR i henhold til ............................... EN 60 947-5-6
Mekanisk kontakt
Frekvensområde.......................................... 0...5 kHz
Impulslængde.............................................. > 0,1 ms
Indgangsmodstand ..................................... 1 k
Ω
Trig-niveau, signal ....................................... < 1,2 mA, > 2,1 mA
Trig-niveau, kabelfejl ................................... < 0,1 mA, > 6,5 mA
Udgange:
Relæudgange:
Frekvens max. ............................................. 20 Hz
Max. spænding ........................................... 250 VRMS
Max. strøm .................................................. 2 A / AC
Max. AC effekt ........................................... 100 VA
Max. belastning ved 24 VDC ...................... 1 A
Åben kollektor, NPN-udgange:
Max. frekvens .............................................. 5 kHz
Impulslængde.............................................. > 0,1 ms
Belastning, max. strøm / spænding............ 80 mA / 30 VDC
Spændingsdrop ved 25 mA / 80 mA .......... < 0,75 VDC / < 2,5 VDC
Ex-data:
Klemme 41...43, (51...53)
U
m
............................................................... : 250 V
U
o
................................................................ : 10,6 VDC
I
o
.................................................................. : 13,8 mADC
P
o
................................................................ : 38 mW
L
o
................................................................ : 160 mH
C
o
................................................................ : 1,9 µF
EEx-godkendelse CENELEC:
DEMKO 99 ................................................ ATEX 127186
ATEX .......................................................... 0539 II (1) G
[EEx ia] IIC
Anvendes for zone ...................................... 0, 1 eller 2
10
Содержание 5202B
Страница 9: ...BLOKDIAGRAM 5202B4 15 14 BLOKDIAGRAM 5202B1 OG B2 ...
Страница 17: ...BLOCK DIAGRAM 5202B4 BLOCK DIAGRAM 5202B1 AND 5202B2 31 30 ...
Страница 25: ...SCHEMA DE PRINCIPE 5202B4 47 SCHEMA DE PRINCIPE 5202B1 ET 5202B2 46 ...
Страница 33: ...BLOCKDIAGRAMM 5202B4 63 BLOCKDIAGRAMM 5202B1 UND 5202B2 62 ...
Страница 34: ...64 ...