DECLARATION OF CONFORMITY
As manufacturer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hereby declares that the following product:
Type: 5105B
Name: Ex-isolated driver
is in conformity with the following directives and standards:
EMC directive 89/336/EEC and later amendments
From serial no.: 990246001 ff
EN 61 326
EN 50 081-1, EN 50 081-2
EN 50 082-1, EN 50 082-2
This declaration is issued in compliance with article 10, subclause 1 of the EMC
directive. For specification of the acceptable EMC performance level, refer to
the electrical specifications for the module.
The Low Voltage directive 73/23/EEC and later amendments
from serial no.: 990246001 ff
EN 61 010-1
The ATEX directive 94/9/EC and later amendments
From serial no.: 990246001 ff
EN 50 014 and EN 50 020
Ex certificate: 99 ATEX 126014
Notified body for CENELEC/ATEX: UL International Demko A/S 0539
Rønde, 6 Sep. 1999 Peter Rasmussen
Manufacturer’s signature
19
MOUNTING:
Only technicians who are familiar with the technical terms, warnings, and
instructions in the manual and who are able to follow these should connect the
module.
Should there be any doubt as to the correct handling of the module, please
contact your local distributor or, alternatively,
PR electronics A/S, Lerbakken 10, DK-8410 Rønde, Denmark,
tel: +45 86 37 26 77.
Mounting and connection of the module should comply with national legislation
for mounting of electric materials, i.a. wire cross section, protective fuse, and
location. Descriptions of input / output and supply connections are shown in
the block diagram and side label.
The following apply to fixed hazardous voltages-connected modules:
The max. size of the protective fuse is 10 A and, together with a power switch,
it should be easily accessible and close to the module.
The power switch should be marked with a label telling it will switch off the
voltage to the module.
CALIBRATION AND ADJUSTMENT:
During calibration and adjustment, the measuring and connection of external
voltages must be carried out according to the specifications of this manual. The
technician must use tools and instruments that are safe to use.
NORMAL OPERATION:
Operators are only allowed to adjust and operate modules that are safely fixed
in panels, etc., thus avoiding the danger of personal injury and damage. This
means there is no electrical shock hazard, and the module is easily accessible.
CLEANING:
When disconnected, the module may be cleaned with a cloth moistened with
distilled water or ethyl alcohol.
LIABILITY:
To the extent the instructions in this manual are not strictly observed, the
custom er cannot advance a demand against PR electronics A/S that would
otherwise exist according to the concluded sales agreement.