7
8. Test Light
Check M, N electrode loop if communicated, press the the button, the light up is normal.
9. Charge
Instrument uses DC / 12V / 4500mAh rechargeable battery, should be charged before using.
Charger is suitable for AC / 110-220V AC power, the charger is red when charging, after full
turned to green light. Charging time 4-8 hours. ( Only could be charged after turned off the
machine ) .
The use of the Instrument (PQWT-S150 as the sample)
Instrument Works Introduction
By the M, N electrode probe ( transducer ) via a cable earth's magnetic field to electrical signal
input to high impedance input stage , after the anti-jamming exchange amplification, frequency
selection, select the desired operating frequency, and then by the A / D sampling, central processor
(CPU) for data processing. Where in the entire measurement process, high-speed central
processing unit (CPU) of the control, instrumentation automatic range conversion and automatic
frequency selection . The last display of measured data and curves from the LCD graphic, through
computer data and curves print or transmit it. Depending on the abnormal curves and data can be
carried out data analysis, make geological conclusion. .
After connecting the instrument by instrument straps , back in the body for convenience. Power on
the instrument display automatically enters the instrument main screen and operating mode after
boot LOGO and company information.
Main Screen Description
Boot into the boot screen (Figure 1) , after a successful start into the main screen (Figure 2 ) , as
shown below:
Figure 1 Boot Screen