background image

 

 

2)

 

Solar Charging: The PPT Powerpack 400 is ready for solar connection. With integrated 10A 
solar regulator and dedicated Solar input connection charge your PPT Powerpack 400 
using the power of the Sun. The maximum recommended total solar panel input is 150W. 
The PV panel output must be for 12V charging only (ie panel output voltage Vmp is approx. 
17.5V). The supplied solar cable has ends prepared with MC4 connectors for a direct link to 
a solar panel with the same connections. The 3pin connector should be inserted into the 
solar connector (Front view right side panel 

 See Section 2.4 b). On successful connection 

and in daylight the red LED charging light will be on. The PPT Powerpack 400 can be used 
during solar charging and once fully charged the solar panel can be left connected if 
required since the regulator will ensure the PPT Powerpack 400 is not over charged. 

 
 

c)

 

Adding External Battery using supplied cable 

The PPT Powerpack 400 battery capacity can be extended by connecting an external leisure battery. 

The  internal  battery  of  the  powerpack  400  is  18AH.  By  connecting  a  further  battery  using  the 

External battery cable essentially puts this battery in parallel to it to further increase the AH rating 
eg. Internal battery 18AH + External battery 60AH = 78AH

 

The connection to the external battery is made using the supplied cable. One end is terminated with 

a large connector that connects to the EXT Battery connector on the PPT Powerpack 400. The other 

end has crocodile clips for direct connection to the external battery.  There is an inline fuse holder 
with 40A fuse on the cables to protect against short circuit.

 

Once the connection is made any charging via solar panel will be to both batteries. Any charging 

indicators and battery check LED lights will now indicate based on the battery bank.

 

 

 

 

5-

 

Maintenance and Warnings 

 

 

To prevent fire hazard do not obstruct ventilation overheating could occur 

 

 

Keep away from fire or any corrosives

 

 

Risk of electrical shock, do not remove cover when in use.

 

 

Reverse polarity connection will blow internal battery fuse

 

 

Unit is not waterproof, water damage is not covered by the warranty

 

 

Ensure all connections are secure before use

 

 

If product becomes dirty simply wipe down with a damp cloth

 

 
 

 

 

 

6-

 

Warranty 

Содержание Powerpack 400

Страница 1: ...1 PPT Powerpack 400 User Manual Please Read this Manual carefully before using ...

Страница 2: ...fully before use and retain them for future reference If any modification is made it may damage the product and void any warranty Content 1 Introduction and Overview 3 2 Features and Functions 4 3 Using the Power Inverter Function 7 4 Using the Supplied Accessories 7 5 Maintenance and Warnings 8 6 Warranty 9 7 Troubleshooting 9 8 Contact 9 ...

Страница 3: ...tery Fuse This can be found by sliding down the side panel Then clip on fuse covers supplied in bag over each fuse marked Internal and External Specifications Inverter Output Power 400W Inverter Output Voltage 230Vac AC outlet 1 x universal socket DC outlet 12Vdc 10A unregulated USB outlet 5V 1A Battery 18AH SLA Battery Solar Regulator 10A Fuses 40A blade Dimensions W 410 D 110 H 370mm Weight 12KG...

Страница 4: ... ON position b USB Output Connect a USB cable not supplied to charge mobile phones and other portable devices c Battery Check Press the black switch to check the battery status The coloured LED s light up accordingly to show the battery status d 2 Watt LED Light Integrated to front panel ON OFF switch on rear side ...

Страница 5: ...Inverter is ON e Battery Low Green LED light Indicates Internal battery or internal and external if connected is low f Load 80 red LED light Indicates inverter is at 80 of max rating 400 watts g Charging Red LED light Indicates the batteries are being charged either from the AC charger or from solar panel input h 100 Green LED light Indicates the batteries are fully charged i Charger Input connect...

Страница 6: ...s 3 pin input connector as supplied with PPT Powerpack 400 The maximum input is 10 Amps See Section 3 b 2 for more info c External Battery Fuse Protects external batteries if connected d Internal Battery Fuse Protects internal battery NOTE This fuse must be inserted for the unit to operate properly e EXT Battery External battery connection Using the supplied cable a further external battery can be...

Страница 7: ...he supplied lighting adapter is designed for connection to the 12VDC socket See section 2 2 c to provide simple and safe connection of lights to the PPT Powerpack 400 The Lighting Adapter will accommodate up to five of the PPT light strips These LED light strips are supplied separately and are available to order from Portable Power Technology The 30 LED light strips are designed at 7 Watts each to...

Страница 8: ...ernal battery of the powerpack 400 is 18AH By connecting a further battery using the External battery cable essentially puts this battery in parallel to it to further increase the AH rating eg Internal battery 18AH External battery 60AH 78AH The connection to the external battery is made using the supplied cable One end is terminated with a large connector that connects to the EXT Battery connecto...

Страница 9: ...et the switch inverter OFF then ON again Battery not charging Check connection to solar panel AC charger Check external battery fuse Unit is clicking when AC charger is connected or solar panel is connected Check internal battery fuse see section 2 4d Unit has been left on and is fully discharged the unit will not recharge Connect external battery cable to a known charged battery Leave 10 mins Dis...