background image

 

 

3-

 

Using the Power Inverter Function 

 

Slide down the left side panel to reveal the universal 3 pin socket. Ensuring that the inverter 
switch is in the OFF position (see 2.2 b) connect the load to be powered and then push the 
inverter switch to the ON position. The appliance connected to the inverter should now turn 
on. If the overload light comes on and the load turns off then the appliance exceeds the rating 
of the inverter (400 watts). To reset the inverter simply reset the inverter switch to OFF and 
then ON again. 
The inverter will power loads connected to it for as long as the battery capacity allows. The 
higher the wattage the shorter the time.  The PPT Powerpack 400 is designed to power small 
loads such as lights, TV, radio, dvd player and other portable devices.  

 

TV 

 60 Watts Approx run time = 2 hours* 

 

3 x 30 LED lights strips (optional accessory) 

 21 Watts Approx run time = 6 Hours* 

 

Small Power Drill 

 400 Watts Approx run time = 10-15 minutes* 

NOTE *

 Assumes only internal 18AH is being used with no further external battery 

 

4-

 

Using the Supplied Accessories 

 

The PPT Powerpack 400 is supplied with accessories to provide additional features or functionality to 
the product 

a)

 

Lighting Adapter 

 The supplied lighting adapter is designed for connection to the 12VDC 

socket (See section 2.2 c) to provide simple and safe connection of lights to the  
PPT Powerpack 400. The Lighting Adapter will accommodate up to five of the PPT light strips. 
These LED light strips are supplied separately and are available to order from Portable Power 
Technology. The 30 LED light strips are designed at 7 Watts each to be energy efficient whilst 
providing very high light output making them ideal for off grid locations, camping or on market 
stalls and exhibitions. 
 

b)

 

Charging the PPT Powerpack 400 

 The PPT Powerpack 400 can either be charged using the 

supplied AC charger or by connection of a suitable solar panel using the supplied cable. 

 

1)

 

AC Charging: Ensure the main unit switch is in OFF position.  Plug the jack plug into the 
charger input socket on the rear of the unit (See Section 2.2 i). Plug into mains supply and 
switch on. The Red charging LED will be on (See Section 2.2 g). When charging has 
completed the 100% Green LED will be on. Please note that the 2A AC charger is not 
recommended for charging the PPT Powerpack 400 if an external battery is also connected 
and if it exceeds 20AH. Charging will take too long the supplied 2A charger is not suitable. If 
AC charging of an external b Internal battery is required we would recommend the 
use of a >5A charger. Please call 01474 761051 for advice. 

Содержание Powerpack 400

Страница 1: ...1 PPT Powerpack 400 User Manual Please Read this Manual carefully before using ...

Страница 2: ...fully before use and retain them for future reference If any modification is made it may damage the product and void any warranty Content 1 Introduction and Overview 3 2 Features and Functions 4 3 Using the Power Inverter Function 7 4 Using the Supplied Accessories 7 5 Maintenance and Warnings 8 6 Warranty 9 7 Troubleshooting 9 8 Contact 9 ...

Страница 3: ...tery Fuse This can be found by sliding down the side panel Then clip on fuse covers supplied in bag over each fuse marked Internal and External Specifications Inverter Output Power 400W Inverter Output Voltage 230Vac AC outlet 1 x universal socket DC outlet 12Vdc 10A unregulated USB outlet 5V 1A Battery 18AH SLA Battery Solar Regulator 10A Fuses 40A blade Dimensions W 410 D 110 H 370mm Weight 12KG...

Страница 4: ... ON position b USB Output Connect a USB cable not supplied to charge mobile phones and other portable devices c Battery Check Press the black switch to check the battery status The coloured LED s light up accordingly to show the battery status d 2 Watt LED Light Integrated to front panel ON OFF switch on rear side ...

Страница 5: ...Inverter is ON e Battery Low Green LED light Indicates Internal battery or internal and external if connected is low f Load 80 red LED light Indicates inverter is at 80 of max rating 400 watts g Charging Red LED light Indicates the batteries are being charged either from the AC charger or from solar panel input h 100 Green LED light Indicates the batteries are fully charged i Charger Input connect...

Страница 6: ...s 3 pin input connector as supplied with PPT Powerpack 400 The maximum input is 10 Amps See Section 3 b 2 for more info c External Battery Fuse Protects external batteries if connected d Internal Battery Fuse Protects internal battery NOTE This fuse must be inserted for the unit to operate properly e EXT Battery External battery connection Using the supplied cable a further external battery can be...

Страница 7: ...he supplied lighting adapter is designed for connection to the 12VDC socket See section 2 2 c to provide simple and safe connection of lights to the PPT Powerpack 400 The Lighting Adapter will accommodate up to five of the PPT light strips These LED light strips are supplied separately and are available to order from Portable Power Technology The 30 LED light strips are designed at 7 Watts each to...

Страница 8: ...ernal battery of the powerpack 400 is 18AH By connecting a further battery using the External battery cable essentially puts this battery in parallel to it to further increase the AH rating eg Internal battery 18AH External battery 60AH 78AH The connection to the external battery is made using the supplied cable One end is terminated with a large connector that connects to the EXT Battery connecto...

Страница 9: ...et the switch inverter OFF then ON again Battery not charging Check connection to solar panel AC charger Check external battery fuse Unit is clicking when AC charger is connected or solar panel is connected Check internal battery fuse see section 2 4d Unit has been left on and is fully discharged the unit will not recharge Connect external battery cable to a known charged battery Leave 10 mins Dis...