EXT HEAT:
Selecting External heat control mode.
(only when unit is in “HEAT CONT = EXT” mode.
MOMENT: On or off by contact of E- HEAT terminal of TB2 on EXT-TERM
board (close=On, open=Off)
LATCH: Latch On or latch off alternately by contact close triggering of E-
HEAT terminal of TB2 on EXT-TERM board.
EXT RESET:
Selecting external reset function: enable or disable.
DISABLE:
ENABLE:
EXT E.STOP:
Selecting external emergency stop function: enable or disable.
DISABLE:
ENABLE: In this case, E- STOP terminal of TB2 on EXT-TERM board should
be closed in normal operation.
AUX INT:
Selecting auxiliary interlock: enable or disable.
DISABLE:
ENABLE: In this case, AUX-INT terminal of TB2 on EXT-TERM board should
be closed in normal operation.
POWER CONT:
Selecting source for output power control under manual mode.
LOCAL: Output power controlled by panel knob.
EXT 0-5V: Output power controlled by Voltage level of P-DEMD terminal of
TB1 on EXT-TERM board (5V=100%)
EXT 4-20mA: Output power controlled by current level of P-DEMD terminal of
TB1 on EXT-TERM board (4mA=0%, 20mA=100%)
(Terminated with 250 ohm internal)
When EXT 0-5V or EXT4-20mA selected, SW2 must be set as same name on
EXT-TERM board.
FBK MODE:
Selecting source of object control power.
POWER:
CAP.V:
INV.C:
AUX 0-5V:
AUX 4-20mA:
(When EXT 0-5V or EXT4-20mA selected, SW3 must be set as same name on
EXT-TERM board.)
In this mode the operator can select which function to control on the power
potentiometer, provided the load does not change. Example: Selecting POWER:
when the potentiometer is set to 50% the power supply will try to deliver 50%
power or 12.5kW. If selected CAP.V, 50% demand will result in 50% of 500volts
or 250V. For INV.C, 50% demand will display 250A. (Given no limits are
reached). If the load changes accuracy is around 15%.
5.1.3. Job select
Selecting job profile: enter PROGRAMMED mode operation. Selected job number
displayed on the Program status indicator.
1. Select “JOB SELECT” in the PROGRAM menu.
2. Enter a job number(1~15) with numeric keys and press “ENT” key to select the
16