When Manual is in continuous mode: “MANUAL [CONT]” displays on 1
st
line of LCD,
When Manual is in timed mode: “MANUAL [T=0.0S] displays on 1
st
line of LCD.
1) Operation in Manual continuous mode.
Press START switch to heat on and press STOP switch to heat off.
If current mode is in manual timed, you can change the mode by pressing
RIGHT (►) key for 1 sec. or more to manual continuous mode.
2) Operation in Manual timed mode.
Press START switch to heat on and unit will stop after the set time has ended.
If current mode is manual continuous, you can change the mode by pressing
LEFT (◄) key for 1 sec. or more to manual timed mode and the LCD [T=0.0S]
will blink. You can enter the time you want to change with numeric keys and then
press ENT key to save.
4.2.2. Programmed mode operation
Select Programmed mode in the programming if current mode is manual. (see
section 5.1.)
PROGRAMMED LOC
>> POWER LIMIT
P.S=50% C.V=500V
I.C=300A FRQ=370KHz
Press START switch to start process, the unit follows the selected job profile
and then stops.
See section 5.1., for programming job profile.
5. Programming & Status monitor
5.1. Programming
The power supply can be programmed to control the functions below through the menu.
1) Control mode :
Operating mode
Heat control mode
External heat control
External reset control
External emergency stop