2.2.5
SC/APC Connectors
To connect SC/APC optical connectors follow these steps:
Remove the plug protective cover.
Align the connector keyway slot in the adaptor to the key of the plug.
Gently push the plug-into the adapter until a click is heard and the connector locks.
To disconnect follow these steps:
Grip the body of the plug and gently pull the plug from the adaptor, replace the protective cover.
Only connect SC/APC cable to SC/APC receptacles.
2.2.6
E2000/APC Connectors
All
ViaLiteHD
E2000 connectorised modules use E2000/APC. Clean the plug before inserting.
To connect E2000/APC optical connectors:-
Gently push the plug-into the E2000/APC adapter.
The cover will automatically disengage.
Push until a click is heard and the connector locks.
To disconnect:-
To disconnect, depress the lever at the rear of the connector and withdraw the connector.
The protective cover automatically engages when removed.
Only connect E2000/APC cable to E2000/APC adaptors.
2.2.7
Minimum bend radius
Because optical fibre is made of glass, it is important not to subject it to excessive stress. For this
reason, each type of cable has a minimum bend radius (MBR) specification, beyond which the cable
cannot be bent without permanent damage occurring. Systems using longer wavelength (i.e.
1550nm) are less tolerant to small bend radii.
The minimum bend radius of standard SMF28 fibre optic cable fitted to
ViaLiteHD
modules is 50mm.
MBR specifications for
ViaLite Communications
supplied fibre optic cables are given in the
ViaLite
Classic
and
ViaLiteHD
System Handbooks Lxx-HB and Hxx-HB respectively.