INTRODUCTION 

The 8072 Dew Point Monitor is ideal for checking the operation of a dryer or confirming 
the dryness of plastic resin in a hopper.  The monitor draws process air from the dryer or 
hopper into an internal manifold containing a sensor which provides dew point 
measurement. 

SPECIFICATIONS: 

Dew Point Range

  

-40

F to +15



F (-40

C to -9

C) 

Sensor Part #

 

1205DM 

Accuracy

 

±3

Alarm Set Point

-10

F (-23



C) Adjustable  

Recorder Output

 

4-20mA scaled as -40

F to +70

F (0-5V optional) 

mA = DP + 67.5      

or     V = DP + 40 

6.875

22 

-40

F = 4mA or 0V     

70

F = 20mA or 5V 

Indicators

 

GREEN LIGHT during "dry" condition 
RED 

LIGHT 

and 

BEEPER during high dew point 

Power Requirements

  

10% (230VAC optional)  
50/60Hz 

Power Consumption

  

5 Watts 

Pump Specifications

 

Flow: 2.5 L/min (0.08 SCFM) 
Vacuum: 

 

6.8" 

of 

Hg 

Pressure: 

 

3.2 

psi 

(All 

pump 

specifications 

are 

nominal) 

Dimensions

 

8072 Carrying Case - 9" x 12-1/2" x 5" Deep 

Weight

 

lbs. 

shipping 

Отзывы: