PPA PIVO HOME Скачать руководство пользователя страница 3

4

5

TECHNICAL FEATURES

* The operator is available with ANALOG, DIGITAL or HYBRID limit switch systems. Check the model on its 

carton or label.

** The maximum length is determined by the operator model, either Standard (1.5 m / ~5 ft) or Super (3 

m / ~10 ft).

BASIC TOOLS NEEDED FOR 
INSTALLATION

Tools needed:

ELECTRICAL CONNECTIONS

For the electrical set-up, the power grid must have the following features:

- 127 V / 220 V Power Supply;

- 5A Circuit Breakers in the Electrical Panel;

- 3/4” diameter conduits between the electrical panel and the disconnection device;

- 3/4” diameter conduits between the disconnection device and the outlet;

- 1/2” diameter conduits for (optional) external pushbuttons;

- 1/2” diameter conduits for photocells (required).

LINEMAN’S 

PLIERS

HACKSAW

HEX NUT DRIVER

SCREWDRIVER

OPEN-END WRENCH

STEPLADDER

WELDING MACHINE

HAMMER

SPIRIT LEVEL

TAPE MEASURE

TRY SQUARE

ELECTRIC DRILL

PENCIL

ELECTRIC SANDER / 

HAND GRINDER

PIVO HOME

CUSTOM

PIVO HOME

PIVO HOME

CUSTOM JETFLEX

PIVO HOME 

JETFLEX

TYPE OF GATE 

OPERATOR

Swing

Swing

Swing

Swing

MOTOR

Single-phase

Single-phase

JetFlex

JetFlex

POWER SUPPLY

127V/220V

127V/220V

127V/220V

127V/220V

RATED FREQUENCY

60 Hz

60 Hz

60 Hz

60 Hz

RATED POWER

320W/470W

370W/500W

300W/290W

350W/330W

MOTOR RPM

1740

1740

1740

5800

RATED CURRENT

2.7A/2.2A

3.1A/2.2A

3.4A/2.3A

3.6A/2.4A

REDUCTION RATIO

1:30

1:23

1:30

1:23

LINEAR SPEED

1.75meter/minute 2.3meters/minute 5.8meters/minute 7.6meters/minute

CYCLES / HOUR

20

30

30

40

PROTECTION RATING

IPX4

IPX4

IPX4

IPX4

OPERATING 

TEMPERATURE

-5°C/+50°C

(23°F/122°F)

-5°C/+50°C

(23°F/122°F)

-5°C/+50°C

(23°F/122°F)

-5°C/+50°C

(23°F/122°F)

INSULATION SYSTEM

Class B, 130°C

(266°F)

Class B, 130°C

(266°F)

Class B, 130°C

(266°F)

Class B, 130°C

(266°F)

LIMIT SWITCH 

SYSTEM

Analog

Analog

Hybrid (Analog 

and digital)

Hybrid (Analog 

and digital)

MAX LEAF WEIGHT

~221lb (100Kg)

~276lb (125Kg)

~331lb (150Kg)

~386lb (175Kg)

MAX LEAF SIZE

HEIGHT = ~8.3 ft

(2.5m) 

LENGTH* =

(According to each

gate operator

model)

HEIGHT = ~8.3 ft

(2.5m) 

LENGTH* =

(According to each

gate operator

model)

HEIGHT = ~8.3 ft

(2.5m) 

LENGTH* =

(According to each

gate operator

model)

HEIGHT = ~8.3 ft

(2.5m) 

LENGTH* =

(According to each

gate operator

model)

Содержание PIVO HOME

Страница 1: ...this manual first Technical Manual P09834 11 2021 Rev 0 Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Industrial Gar a SP CEP 17406 200 Br...

Страница 2: ...t the local grid power complies with the technical data appearing on the gate s label Do not connect the operator to the source ofpoweruntiltheinstallation maintenance or servicing is over Proceed the...

Страница 3: ...PIVO HOME JETFLEX TYPE OF GATE OPERATOR Swing Swing Swing Swing MOTOR Single phase Single phase JetFlex JetFlex POWER SUPPLY 127V 220V 127V 220V 127V 220V 127V 220V RATED FREQUENCY 60 Hz 60 Hz 60 Hz 6...

Страница 4: ...e installation Check the effort required to open close the gate One must be able to perform it smoothly on the entirety of its movement In order to check such effort move the gate 80 cm 2 63 ft away f...

Страница 5: ...ge and at the desired height to mount the operator according to the picture below Step 3 Weld the fastening base according to the instructions pictures below INSTALLATION FOR OPERATORS WITHOUT MECHANI...

Страница 6: ...ccording to the instructions pictures below Step 5 Fit the gear motor to the fastening base tighten the M10 x 45 screw and fix it by means of a M10 hex nut provided according to the picture below FAST...

Страница 7: ...x 6 screws fixed on the reeds and connect it to the control board Before running the operator one must screw the operator housing by means of the 4 provided 3 5 x 16 mm screws CONTROL UNIT Check on th...

Страница 8: ...D Substitute the analog and or digital limit switch system Motor won t run A Reversed wiring B Gate or operator jammed A Check the wiring B Change to manual mode and check it separately Control board...