INSTALLING THE ANALOG LIMIT SWITCH
Step 1:
With the gate closed, place the magnet holder assembly, placed facing the
operator reed. This magnet is the ‘Closed’ Limit Switch.
Step 2:
Totally open the gate and place the other magnet holder assembly on the
rack bar, facing the operator reed. This magnet is the ‘Open’ Limit Switch.
Step 3:
Run the motor and check if the reeds are correctly turning off. If necessary,
reverse the connector of the control board.
After mounting the magnet holder assemblies, perform the final adjustments, mo-
ving them left / right or up / down, according to the desired adjustment.
Step 4:
In order to finish the installation procedure, one must screw the operator
housing by using the 2 provided 3,5 X 16 mm screws.