Step 6:
Position the automation vertically on the door column and weld the mounting
brackets on the column, respecting the measurements in the figure below.
Step 7:
Attach the drive lever to the pin of the drive nut of the operator.
Step 8:
Weld the drive lever on the gate leaf, keeping the distance of 250 mm
between the center of the gate shaft and the center of the lever’s turning point.
110
mm
270 mm
TRIGGERING
NUT
TRACTION
LEVER
LEVER
TURNING POINT
250 mm
GATE AXIS
Step 9:
With the gate closed, maintain a 50 mm tilt on the drive lever, respecting
a distance from the center of the turning point of the drive lever and the center of
the drive nut pin.
Step 10:
Still with the gate closed, adjust the closing stop, so that the rubber of
the gate cushion the drive nut in the closing of the gate. Then, with the gate open,
perform the same procedure for the opening stop.
ANALOGIC LIMIT SWITCH INSTALLATION
Step 1:
Position the limit switch magnet into the drive nut housing. Position the
opening and closing limit switches so that they activate when the gate leaf com-
pletes its movement. Connect the limit switch to the control unit.
Step 2:
Place the protective rubber of the wires into the reed housing, traversing
the entire rail profile.
PIN CENTER OF
THE TRIGGERING
NUT
50 mm
TURNING POINT
OF THE DRIVE
LEVER
TRIGGERING
NUT
REED
MAGNET