16.1.Application of multi-function output
.(1) alarm output
CODE
Description
Range of setting
Refer. value
F0.11
command source
selection
1:Terminal command channel (LED ON)
1
F1.00
DI1 function selection
Forward rotation
1
F1.03
DI4 function selection
Fault reset
9
F2.02
Relay output selection
0: No output 1:motorforward running 2.Fault output 3:Frequency level
detection FDT output 4:Frequency arrival 5:in Zero speed
operation .6
~
40:Reserved
2
Parameters setting
When alarm happen ,the normal open
relay will close ,the KM1 will be on,
the main switch will be open and cut
off the main circuit .The alarm light will
be on as well to show there is alarm .
5A/250VAC
5A/30VDC
DI1