Powtran PI500A-S 004G1 Скачать руководство пользователя страница 12

12 / 20

E0.03 (wake-up delay time), E0.09 (sleep frequency) and E0.11 (sleep delay time) functions only work

when the sleep function setting (F6.13=1) is effective.

F6.17 Power correction coefficient

0.00

10.00

1.00

F6.20 Keyboard lock selection

0: Only RUN and STOP keys are valid.

2: Only RUN, STOP, UP, DOWN keys are

valid

3: Only STOP key is valid; Note: Keyboard

potentiometer is not restricted by this

function.

0

F6.21 QUICK key function selection

0: No function;

1: Click

operation;

2: Shift key switching display state;

3: Forward and reverse switching;

4: Clear UP/DOWN settings;

5: Free shutdown;

6: Realize the switching of the given mode of

running commands in order:

1

F7 group Auxiliary Functional Parameters Group

Code

Parameter name

Setting range

Factory

setting

Change

F7.00 Jog running frequency

0.00Hz~F0.19(Maximum frequency)

6.00Hz

F7.01 Jog acceleration time

0.0s~6500.0s

5.0s

F7.02 Jog deceleration time

0.0s~6500.0s

5.0s

F7.03 Jog priority

0:Invalid

1: Valid

1

F7.04 Jump frequency 1

0.00Hz~F0.19 (Maximum frequency)

0.00Hz

F7.05 Jump frequency 2

0.00Hz~F0.19(Maximum frequency)

0.00Hz

F7.06 Jump frequency range

0.00Hz~F0.19 (Maximum frequency)

0.00Hz

F7.07 Jump frequency availability

during ac/deceleration process

0: Invalid

1: Valid

0

F7.08 Acceleration time 2

0.0s~6500.0s

Depends on

models

F7.09 Deceleration time 2

0.0s~6500.0s

Depends on

models

F7.10 Acceleration time 3

0.0s~6500.0s

Depends on

models

F7.11 Deceleration time 3

0.0s~6500.0s

Depends on

models

F7.12 Acceleration time 4

0.0s~6500.0s

Depends on

models

F7.13 Deceleration time 4

0.0s~6500.0s

Depends on

models

F7.14

Switching frequency point

between acceleration time 1 and

acceleration time 2

0.00Hz~F0.19 (Maximum frequency)

0.00Hz

F7.15

Switching frequency point

between deceleration time 1 and

deceleration time 2

0.00Hz~F0.19 (Maximum frequency)

0.00Hz

F7.16 Forward/reverse rotation

deadband

0.00s~3600.0s

0.00s

F7.17 Reverse rotation control

0: Enable

1: Disable

0

F7.18 Set frequency lower than lower

limit frequency mode

0: Running at lower limit frequency

1: Stop

2: zero speed running

0

F7.19 Droop control

0.00Hz~10.00Hz

0.00Hz

F7.20 Setting cumulative power-on

arrival time

0h~36000h

0h

F7.21 Setting cumulative running arrival

time

0h~36000h

0h

F7.22 Start protection selection

0: OFF

1: ON

0

F7.23 Frequency detection value (FDT1) 0.00Hz~F0.19(Maximum frequency)

50.00Hz

F7.24 Frequency detection hysteresis

value (FDT1)

0.0%~100.0% (FDT1 level)

5.0%

F7.25 Frequency reaches detection width 0.00~100% (Maximum frequency)

0.0%

F7.26 Frequency detection value (FDT2) 0.00Hz~F0.19 (Maximum frequency)

50.00Hz

F7.27 Frequency detection hysteresis

value (FDT2)

0.0%~100.0% (FDT2 level)

5.0%

F7.28 Random arrivals frequency

detection value 1

0.00Hz~F0.19 (Maximum frequency)

50.00Hz

F7.29 Random arrivals frequency

detection width 1

0.00%~100.0% (Maximum frequency)

0.0%

F7.30 Random arrivals frequency

detection value 2

0.00Hz~F0.19 (Maximum frequency)

50.00Hz

F7.31 Random arrivals frequency

detection width 2

0.00%~100.0% (Maximum frequency)

0.0%

F7.32 Zero current detection level

0.0%~300.0% (Rated motor current)

5.0%

F7.33 Zero current detection delay time

0.01s~360.00s

0.10s

F7.34 Overrun value of output current

0.0% (not detected)

0.1%~300.0% (Rated motor current)

200.0%

F7.35 Output current overrun detection

delay time

0.00s~360.00s

0.00s

F7.36 Random arrivals current 1

0.0%~300.0% (Rated motor current)

-100.0%

F7.37 Random arrivals current 1 width

0.0%~300.0% (Rated motor current)

0.0%

F7.38 Random arrivals current 2

0.0%~300.0% (Rated motor current)

-100.0%

Содержание PI500A-S 004G1

Страница 1: ...PI500A S Series Special Solar Inverter For Water Pump English Manual www powtran com...

Страница 2: ...y period please fill out the warranty card and fix it to our authorized dealer 2 Instructions on nameplate Model Designation Powtran Inverter PI 500A S 2R2 G 3 Rated Output Power 2R2 2 2kW 004 4kW Ser...

Страница 3: ...63 185 90 146 154 65 174 5 72 5 1 6 PI500A S 0R7G2 0 75 PI500A S 1R5G2 1 5 PI500A S 2R2G2 2 2 163 185 90 166 174 65 174 5 72 5 1 8 PI500A S 004G2 4 238 260 120 182 190 90 250 5 2 7 PI500A S 5R5G2 5 5...

Страница 4: ...ey is subject to F6 00 Enter Key Enter the menu screen step by step set the parameter confirmation Quick Multifunction Key This key function is determined by the function code F6 21 Keyboard Encoder F...

Страница 5: ...panel control terminals and serial communication port They can be switched through a variety of ways Frequency source Total 8 frequency sources digital analog voltage multi speed and serial port They...

Страница 6: ...ments of all terminals select accessories correctly such as voltmeter input power supply etc 5 Please check the wiring correctly after completion and power on after confirmation 7 The load is a single...

Страница 7: ...motor nameplate Note If the starting current is too large or the motor does not run check whether the V and W phases are connected then check E8 29 3 and then restore the factory value y0 00 3 U V W...

Страница 8: ...24 HDI DI5 pulse frequency HDI DI5 High speed pulse input frequency display unit 1Hz 1Hz d0 25 Communication set value Frequency torque or other command values set by communication port 0 01 d0 27 Mas...

Страница 9: ...cked at the time the parking process of motor is not controlled by the inverter This way is same as the principle of free stop described in F3 07 9 Fault reset RESET The function makes use of terminal...

Страница 10: ...to the function code F7 26 F7 27 s instructions 26 Frequency 1 reaches output Please refer to the function code F7 28 F7 29 s instructions 27 Frequency 2 reaches output Please refer to the function c...

Страница 11: ...0 F4 10 V F overexcitation gain 0 200 80 F4 11 V F oscillation suppression gain 0 100 0 F4 12 V F Separated voltage source 0 9 0 F4 13 Voltage Digital Setting 0V motor rated voltage 0V F4 14 Voltage r...

Страница 12: ...eleration time 2 0 00Hz F0 19 Maximum frequency 0 00Hz F7 15 Switching frequency point between deceleration time 1 and deceleration time 2 0 00Hz F0 19 Maximum frequency 0 00Hz F7 16 Forward reverse r...

Страница 13: ...momentary power cut 0 00s 100 00s 0 50s F8 29 Judgment voltage of momentary power cut action 50 0 100 0 Standard bus voltage 80 F8 30 Load drop protection selection 0 Invalid 1 Valid 0 F8 31 load drop...

Страница 14: ...valid after E0 03 awakens the delay time frequency inverter to start E0 04 Upper limit of MPPT search voltage 0 0 1000 0V Confirmed model typ Search value of upper limit voltage in MPPT search proces...

Страница 15: ...tion Same as E1 19 0 E1 34 8 stage running time T8 0 0s h 6500 0s h 0 0s h E1 35 8 stage ac deceleration time selection Same as E1 19 0 E1 36 9 stage running time T9 0 0s h 6500 0s h 0 0s h E1 37 9 st...

Страница 16: ...motor 0 b0 01 Rated power 0 1 1000 0kW Confirmed model typ b0 02 Rated voltage 1 2000V Confirmed model typ b0 03 Rated current 0 01A 655 35A Inverter power 55kW 0 1A 6553 5A Inverter rate 55kW Confirm...

Страница 17: ...15 Current of the second fault y1 16 Bus voltage of the second fault y1 17 Input terminal status of the second fault y1 19 Output terminal status of the second fault y1 20 Power on time of the second...

Страница 18: ...s high 1 Cancel the external force or install braking resistor 2 Set the voltage to the normal range 8 Err 08 Control power failure 1 The range of input voltage is not within the specification 2 frequ...

Страница 19: ...an the set value of E2 11 Check PID feedback signal or set E2 11 to an appropriate value 40 Err 40 Quick current limiting fault 1 Whether the load is too large or the motor stall occurs 2 The type sel...

Страница 20: ...ing of PI500 PI500A S keyboard installation opening Opening size of external mounting panel T 1 0 1 5mm 126 5 0 2 Mounting panel Opening panel126 5 82 82 0 2 Dimension drawing of keyboard installation...

Отзывы: