![Powtran PI500A-S 004G1 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/powtran/pi500a-s-004g1/pi500a-s-004g1_manual_1592606012.webp)
12 / 20
E0.03 (wake-up delay time), E0.09 (sleep frequency) and E0.11 (sleep delay time) functions only work
when the sleep function setting (F6.13=1) is effective.
F6.17 Power correction coefficient
0.00
~
10.00
1.00
☆
F6.20 Keyboard lock selection
0: Only RUN and STOP keys are valid.
2: Only RUN, STOP, UP, DOWN keys are
valid
3: Only STOP key is valid; Note: Keyboard
potentiometer is not restricted by this
function.
0
☆
F6.21 QUICK key function selection
0: No function;
1: Click
operation;
2: Shift key switching display state;
3: Forward and reverse switching;
4: Clear UP/DOWN settings;
5: Free shutdown;
6: Realize the switching of the given mode of
running commands in order:
1
☆
F7 group Auxiliary Functional Parameters Group
Code
Parameter name
Setting range
Factory
setting
Change
F7.00 Jog running frequency
0.00Hz~F0.19(Maximum frequency)
6.00Hz
☆
F7.01 Jog acceleration time
0.0s~6500.0s
5.0s
☆
F7.02 Jog deceleration time
0.0s~6500.0s
5.0s
☆
F7.03 Jog priority
0:Invalid
1: Valid
1
☆
F7.04 Jump frequency 1
0.00Hz~F0.19 (Maximum frequency)
0.00Hz
☆
F7.05 Jump frequency 2
0.00Hz~F0.19(Maximum frequency)
0.00Hz
☆
F7.06 Jump frequency range
0.00Hz~F0.19 (Maximum frequency)
0.00Hz
☆
F7.07 Jump frequency availability
during ac/deceleration process
0: Invalid
1: Valid
0
☆
F7.08 Acceleration time 2
0.0s~6500.0s
Depends on
models
☆
F7.09 Deceleration time 2
0.0s~6500.0s
Depends on
models
☆
F7.10 Acceleration time 3
0.0s~6500.0s
Depends on
models
☆
F7.11 Deceleration time 3
0.0s~6500.0s
Depends on
models
☆
F7.12 Acceleration time 4
0.0s~6500.0s
Depends on
models
☆
F7.13 Deceleration time 4
0.0s~6500.0s
Depends on
models
☆
F7.14
Switching frequency point
between acceleration time 1 and
acceleration time 2
0.00Hz~F0.19 (Maximum frequency)
0.00Hz
☆
F7.15
Switching frequency point
between deceleration time 1 and
deceleration time 2
0.00Hz~F0.19 (Maximum frequency)
0.00Hz
☆
F7.16 Forward/reverse rotation
deadband
0.00s~3600.0s
0.00s
☆
F7.17 Reverse rotation control
0: Enable
1: Disable
0
☆
F7.18 Set frequency lower than lower
limit frequency mode
0: Running at lower limit frequency
1: Stop
2: zero speed running
0
☆
F7.19 Droop control
0.00Hz~10.00Hz
0.00Hz
☆
F7.20 Setting cumulative power-on
arrival time
0h~36000h
0h
☆
F7.21 Setting cumulative running arrival
time
0h~36000h
0h
☆
F7.22 Start protection selection
0: OFF
1: ON
0
☆
F7.23 Frequency detection value (FDT1) 0.00Hz~F0.19(Maximum frequency)
50.00Hz
☆
F7.24 Frequency detection hysteresis
value (FDT1)
0.0%~100.0% (FDT1 level)
5.0%
☆
F7.25 Frequency reaches detection width 0.00~100% (Maximum frequency)
0.0%
☆
F7.26 Frequency detection value (FDT2) 0.00Hz~F0.19 (Maximum frequency)
50.00Hz
☆
F7.27 Frequency detection hysteresis
value (FDT2)
0.0%~100.0% (FDT2 level)
5.0%
☆
F7.28 Random arrivals frequency
detection value 1
0.00Hz~F0.19 (Maximum frequency)
50.00Hz
☆
F7.29 Random arrivals frequency
detection width 1
0.00%~100.0% (Maximum frequency)
0.0%
☆
F7.30 Random arrivals frequency
detection value 2
0.00Hz~F0.19 (Maximum frequency)
50.00Hz
☆
F7.31 Random arrivals frequency
detection width 2
0.00%~100.0% (Maximum frequency)
0.0%
☆
F7.32 Zero current detection level
0.0%~300.0% (Rated motor current)
5.0%
☆
F7.33 Zero current detection delay time
0.01s~360.00s
0.10s
☆
F7.34 Overrun value of output current
0.0% (not detected)
0.1%~300.0% (Rated motor current)
200.0%
☆
F7.35 Output current overrun detection
delay time
0.00s~360.00s
0.00s
☆
F7.36 Random arrivals current 1
0.0%~300.0% (Rated motor current)
-100.0%
☆
F7.37 Random arrivals current 1 width
0.0%~300.0% (Rated motor current)
0.0%
☆
F7.38 Random arrivals current 2
0.0%~300.0% (Rated motor current)
-100.0%
☆