background image

  3 / 16 

 

Enter Key 

* Enter the menu screen step by step, set the parameter confirmation. 

 

Quick 
Multifunction Key 

*This key function is determined by the function code F6.21. 

 

Keyboard Encoder 

* F0.03 setting to 4, and the keyboard potentiometer setting the 
operating frequency. 

5. 

 

Standard specifications   

Items 

Specifications 

Power Input 

Rated voltage 

AC 1PH 220V(-15%) to 240V(+10%) 
AC 3PH 220V(-15%) to 240V(+10%) 
AC 3PH 380V(-15%) to 440V(+10%) 
AC 3PH 480V(-10%) to 480V(+10%) 

Input frequency   

50Hz/60Hz 

Allowing fluctuations 

Voltage continued 
volatiliy:±10%   

Less than 3% of voltage unbalance rate 3% 

Input frequency 
fluctution:±5%; 

Distortion satisfy IEC61800-2andard; 

Control 

Control system 

High performance vector control inverter based on DSP 

Control method 

V/F control, vector control W/O PG, 

Automatic torque 
boost function 

Realize low frequency (1Hz) and large output torque control under 
the V/F control mode. 

Acceleration/decal 
eration control 

Straight or S-curve mode. Four times available and time range is 0.0 
to 6500.0s. 

V/F curve mode 

Linear, square root/m-th power, custom V/F curve 

Over load capability 

G type:rated current 150% - 1 minute, rated current 180% - 2seconds 
F type:rated current 120% - 1 minute, rated current 150% - 2 seconds 

Maximum frequency  1.Vector control:0 to 300Hz; 2.V/F control:0 to 3200Hz 

Carrier Frequency 

0.5 to 16kHz; automatically adjust carrier frequency according to the 
load characteristics. 

Input frequency 
resolution 

Digital setting: 0.01Hz Analog setting: maximum frequency*0.025% 

Start torque 

G type: 0.5Hz/150% (Vector control W/O PG) 
F type: 0.5Hz/100% (Vector control W/O PG) 

Speed range 

1:100 (Vector control W/O PG)   

Steady-speed precision Vector control W/O PG: ≤ ± 0.5% (rated synchronous speed) 
Torque response 

≤ 40ms (Vector control W/O PG) 

Torque boost 

Automatic torque boost; manual torque boost(0.1% to 30.0%) 

DC braking 

DC braking frequency: 0.0Hz to max. frequency, braking time:0.0 to 
100.0 seconds, braking current value: 0.0% to 100.0% 

Jogging control 

Jog Frequency Range: 0.00Hz to max. frequency;Jog Ac/deceleration 
time: 0.0s to 6500.0s. 

Built-in PID 

Easy to realize closed-loop control system for the process control. 

Automatic voltage 
regulation(AVR) 

Automatically maintain a constant output voltage when the voltage 
of electricity grid changes 

Personalization 

Self-inspection 
ofperipherals after 
power-on 

After powering on, peripheral equipment will perform safety testing, 
such as ground, short circuit, etc. 

Common DC bus 
function 

Multiple inverter can use a common DC bus. 

Quick current limiting 

The current limiting algorithm is used to reduce the inverter over 
current probability, and improve whole unit anti-interference capability. 

Timing control 

Timing control function: time setting range(0m to 6500m) 

Running 

Input 
signal 

DI input 
terminal   

6 digital input terminals, DI5 for high-speed pulse input(0 to 100 
kHz square wave) 

AI1 analog   
input 

1 analog input terminals respectively for optional range (0 to 20mA 
or 0 to 10V), they can be used to set frequency, output frequency 

Multi-speed 

At most 16-speed can be set(Run by using the multi-function 
terminals or program) 

Emergency 
stop 

Interrupt controller output 

Fault reset 

When the protection function is active, you can automatically or 
manually reset the fault condition. 

PID feedback 
signal 

Including DC(0 to 10V), DC(0 to 20mA) 

Output 
Signal 

Output signal 

One way output SPA;One way contact output;One way AD1 analog 
output   

SPA contact 
output   

There are 40 signals each way .Contact capacity : normally open 
contact 5A/AC 250V,1A/DC 30V. 

DA1 analog 
output 

One way analog output,can select frequency, current ,voltage etc 16 
singnals.Output signals can be sent 0 to 10V/0 to 20mA 

Running command 
channel 

Three channels: operation panel, control terminals and serial 
communication port. They can be switched through a variety of 
ways. 

Frequency source 

Total 8 frequency sources: digital, analog voltage,analog current , 
multi-speed and serial port. They can be switched through a variety of 
ways. 

Run function 

Limit frequency, jump frequency, frequency compensation, 
auto-tuning, PID control 

Protection 

function 

Inverter protection 

Overvoltage protection, undervoltage protection, overcurrent 
protection, overload protection, overheat protection, overcurrent stall 
protection, overvoltage stall protection, losting-phase protection 
(optional), communication error, PID feedback signal abnormalities, 
PG failure and short circuit to ground protection. 

Display 

LED 
display 
keyboa rd 

Running 

information 

Monitoring objects including: running frequency, set frequency,bus 
voltage, output voltage, output current, output power, output torque, 
input terminal status, output terminal status, analog AI1 value,, motor 
Actual running speed,PID set value percentage, PID feedback value 
percentage. 

Error 
message 

At most save three error message, and the time, type, voltage,current, 
frequency and work status can be queried when the failure is 
occurred. 

Key lock and function 
selection 

Lock part or all of keys, define the function scope of some keys to 
prevent misuse. 

IGBT temperature 

show the inverter inner IGBT temperature 

Communi cation  RS485 

Built in 485 

Enviroment 

Environment 
temperature 

-10

to 40

 (Temperature at 40 

to 50

, please derating for use) 

Storage temperature 

-20 

 to 65 

 

Environment 
humidity 

Less than 90% R.H, no condensation. 

Vibration 

Below 5.9m/s²

(= 0.6g) 

Application sites 

Indoor where no sunlight or corrosive, explosive gas and water 
vapor, dust, flammable gas,oil mist, water vapor, drip or salt, etc. 

Altitude 

No need degrade use under 1000m,degrade 1% for altitude rise 100m 
when above 1000m,do not use it above 3000m 

Protection level 

IP20 

Содержание PI500 011G2

Страница 1: ...maintenance care For any problem within the warranty period please fill out the warranty card and fix it to our authorized dealer 2 Instructions on nameplate Model designation POWTRAN Inverter PI 500...

Страница 2: ...ops LOCAL REMOTE Command indicator light That is the indicator for keyboard operation terminal operation and remote operation Communication contral ON terminal control working status OFF keyboard cont...

Страница 3: ...range 0m to 6500m Running Input signal DI input terminal 6 digital input terminals DI5 for high speed pulse input 0 to 100 kHz square wave AI1 analog input 1 analog input terminals respectively for o...

Страница 4: ...make sure that there is no mistake before power can be turned on 7 Parameter list In PI500A series frequency inverters some parameters are manufacturer reserved and their serial numbers are not liste...

Страница 5: ...ting 0 Relative to maximum frequency 1 Relative to master frequency source 1 2 Relative to master frequency source 2 0 F0 06 Frequency source auxiliary setting range 0 to 150 100 F0 07 Frequency super...

Страница 6: ...ed to switch between two frequency sources 19 UP DOWN setting Terminal keyboard When the frequency reference is the digital frequency this terminal is used to clear the changed frequency value by term...

Страница 7: ...ad warning is exceeded For motor overload parameter setting refer to function codes F8 02 F8 04 7 Frequency inverter overload forecasting alarm The output signal ON 10 seconds before the overload prot...

Страница 8: ...git SPA Ten thousands digit Relay 2 00000 F2 16 DA1 zero bias coefficient 100 0 to 100 0 0 0 F2 17 DA1 gain 10 00 to 10 00 1 00 F3 group Start stop control parameters group Code Parameter name Setting...

Страница 9: ...verter module radiator temperature 0 0 to 100 0 F6 07 Total run time 0h to 65535h F6 08 Total power on time 0h to 65535h F6 09 Total power consumption 0 to 65535kWh F6 10 Product series number Frequen...

Страница 10: ...0 to 300 0 Rated motor current 0 0 F7 40 Module temperature arrival 0 to 100 75 F7 41 Cooling fan control 0 Fan running only when running 1 Fan always running 0 F7 42 Timing function selection 0 Inval...

Страница 11: ...depth 0 E0 group Pendulum frequency fixed length and counting parameter array Code Parameter name Setting range Factory setting Chan ge E0 00 Swing setting mode 0 Relative to center frequency 1 Relat...

Страница 12: ...h 0 0s h E1 49 15 stage ac deceleration time selection Same as E1 19 0 E1 50 Simple PLC run time unit 0 S seconds 1 H hours 0 E1 51 Multi stage command 0 reference manner 0 Function code E1 00 referen...

Страница 13: ...e Setting range Factory setting Cha nge y0 00 Parameter initialization 0 Nno operation 1 Restore default parameter values not including motor parameters 2 Clear history 3 Restore default parameter val...

Страница 14: ...ppens 2 The control mode is vector and without identification of parameters 3 The deceleration time is too short 4 The voltage is low 5 Suddenly increase the load in the process of deceleration 6 Didn...

Страница 15: ...2 Replace hall device 21 Err 21 Motor parameter auto tuning fault 1 The motor parameters was not set according to the nameplate 2 The identification process of parameter is timeout 1 correctly set mot...

Страница 16: ...yboard compartment Dimension drawing of keyboard compartment dimension unit mm PI500 pI500A keyboard installation opening dimension drawing Mounting panel Opening size of external mounting panel Openi...

Отзывы: