PZN Aquamatic Water Heater 

 Doc Ref M107 issue 1.3 Sep 2018.  

Note: Do not disperse the parts of the 

packaging in the environment, or leave them 

within the reach of children, as they are 

potentially danger. For proper disposal contact 

your local authorities.

The unit is sent in a single case and includes:

−  UNIT HEATER

−  PLASTIC BAG (A) containing:

 

•  Instruction Manual;

 

•  Warranty Certificate;

 

•  Spare Parts catalogue;

 

•  Label with barcode;

The booklet is an integral part of the unit and should be 

read carefully and kept for future reference.

The unit can be identified by either 

 •  the Technical Data plate (positioned on the rear of the 

unit) which shows the main technical /performance data.

•  the packaging label that shows the code, model and 

serial number of the unit.

In case of damage or loss, request a duplicate from 

Technical Assistance.

The location for the unit must be determined by the 

system designer or a competent person and it must 

take into account the technical requirements and the 

standards and regulations in force; generally, special 

permissions need to be obtained. (e.g.: regulations 

concerning zoning, architecture, fires, environmental 

pollution, noise emission, etc.). It is therefore advisable, 

before installing the unit, to request and obtain the 

necessary permissions. 

Note: For proper installation always observe 

the following minimum requisites:

•  position the unit on a dry level surface capable of 

sustaining its weight;

•  respect the distances in order to allow for a correct flow 

of air and normal cleaning and maintenance operations;

•  position the unit in a place that makes water and 

electrical connections convenient;

•  be close to an electric socket;

Note: It is also necessary to make sure that:

The temperature range for use is between -15 

and +40 °C

Warning: It is forbidden to install:

•  in places where there are aggressive 

atmospheres;

•  in narrow places where the noise created by the 

generator could be amplified by reverb or resonance;

•  in corners where there is a deposit of dust, leaves and 

anything that may reduce the efficiency of the unit by 

blocking the air passage.

The unit is normally installed on a shelf in a higher 

position as shown in the following figures. In this case 

make sure that the shelves are attached to a suitable 

structure by means of suitable fixing elements. 

The unit features a helical fan and it is therefore suitable 

to be connected to ducts with important load losses. For 

special requirements, consult the Manufacturer.

Example of installation in a small room:

Example of installation in a large room/area

:

Содержание PZN 12

Страница 1: ...w w w p o w r m a t i c c o u k d e t 4 3 4 e e PZN User Installation Servicing Manual Issue 1 3 September 2018 Doc Ref M107 Issue 1 3 Sep 2018...

Страница 2: ...your behalf Conditions of Guarantee 1 The heater must have been installed by a competent qualified installer and in accordance with the manufacturer s instructions building regulations and local regul...

Страница 3: ...1 Introduction 4 Duties 6 Dimensions 7 1 2 Technical data 8 1 3 General Requirements 16 Installation 2 1 Fitting the unit 19 2 2 Electrical Cable Installation 21 2 3 Wiring Diagrams 22 2 4 Commission...

Страница 4: ...sionally qualified personnel In case of water leaks turn the main switch off and close the water taps Immediately call the Technical Assistance Service or professionally qualified personnel and do not...

Страница 5: ...s safety Do not touch the heater if you are barefoot or if parts of your body are wet Before carrying out any cleaning and or maintenance work on the unit always disconnect the unit from the mains pow...

Страница 6: ...cal h 36720 33630 45060 47760 54180 58220 75510 76370 98810 Rows no 3 2 3 2 3 2 3 2 3 Axial Fan Qty no 1 2 dia mm 400 420 420 550 550 450 450 550 550 rotations rpm 1400 900 700 900 700 Airflow Rate m...

Страница 7: ...40 690 690 690 C mm 90 116 122 172 162 172 D mm 489 539 589 639 689 739 789 1139 Weight kg 14 15 16 18 19 21 23 24 25 28 29 32 40 43 58 63 70 76 Model 12 13 22 23 32 33 42 43 52 53 62 63 72 73 82 83 9...

Страница 8: ...Outlet Temperature C 48 50 53 Water Side Heat Loss kPa 16 14 11 Water Flow Rate l h 598 546 494 PZN 12 13 Single Phase 230V 50Hz Water Temp 85 70 C Fan heater at MAXIMUM fan speed PZN13 Airflow Rate...

Страница 9: ...ir Outlet Temperature C 40 43 46 Water Side Heat Loss kPa 15 12 10 Water Flow Rate l h 953 869 786 PZN 22 23 Single Phase 230V 50Hz Water Temp 85 70 C Fan heater at MAXIMUM fan speed PZN23 Airflow Rat...

Страница 10: ...Air Outlet Temperature C 46 49 52 Water Side Heat Loss kPa 20 17 14 Water Flow Rate l h 1031 941 85215 PZN 32 33 Single Phase 230V 50Hz Water Temp 85 70 C Fan heater at MAXIMUM fan speed PZN33 Airflow...

Страница 11: ...3 Air Outlet Temperature C 50 52 55 Water Side Heat Loss kPa 13 11 10 Water Flow Rate l h 1161 1059 958 PZN 42 43 Single Phase 230V 50Hz Water Temp 85 70 C Fan heater at MAXIMUM fan speed PZN43 Airflo...

Страница 12: ...43 Air Outlet Temperature C 51 53 55 Water Side Heat Loss kPa 11 10 8 Water Flow Rate l h 1371 1251 1132 PZN 52 53 Single Phase 230V 50Hz Water Temp 85 70 C Fan heater at MAXIMUM fan speed PZN53 Airfl...

Страница 13: ...7 Air Outlet Temperature C 49 52 54 Water Side Heat Loss kPa 7 6 5 Water Flow Rate l h 1668 1521 1375 PZN 62 63 Single Phase 230V 50Hz Water Temp 85 70 C Fan heater at MAXIMUM fan speed PZN63 Airflow...

Страница 14: ...44650 Air Flow Rate m h 6200 Sound Pressure Level dB A 52 Air Outlet Temperature C 45 48 50 Water Side Heat Loss kPa 12 10 8 Water Flow Rate l h 3707 3380 3056 Fan heater at MINUMUM fan speed Airflow...

Страница 15: ...r Flow Rate m h 12550 Sound Pressure Level dB A 53 Air Outlet Temperature C 36 39 43 Water Side Heat Loss kPa 21 18 15 Water Flow Rate l h 5229 4773 4321 Fan heater at MINUMUM fan speed Airflow Rate C...

Страница 16: ...letromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC 1 3 3 Handling Handling must be done by properly equipped personnel All units are pack...

Страница 17: ...mental pollution noise emission etc It is therefore advisable before installing the unit to request and obtain the necessary permissions Note For proper installation always observe the following minim...

Страница 18: ...city supply must facilitate the complete electrical isolation of the unit s via a suitable fused isolator see section 2 4 5 for ratings be in a readily accessible position adjacent to the unit s serve...

Страница 19: ...according to the book that is in compliance with the National and Local Standards in force and the instructions provided in this instruction booklet The heaters have been manufactured for room heating...

Страница 20: ...n running a few hours and periodically check pressure check that there are no leaks WARNING If there is a risk of sub zero temperatures mix some anti freeze into the water in manufacturer recommended...

Страница 21: ...conductor if the cable or cord slips out of the cord anchorage All external controls must be of an approved type All units are fully pre wired and only require final connections for the incoming main...

Страница 22: ...50Hz 86 0 38 1 1 5 32 33 230V 50Hz 120 0 55 1 1 5 42 43 230V 50Hz 130 0 60 1 1 5 52 53 230V 50Hz 200 0 90 2 1 5 62 63 230V 50Hz 220 0 95 2 1 5 72 73 400V 3N 50Hz 305 0 70 2 1 5 82 83 400V 3N 50Hz 240...

Страница 23: ...uamatic Water Heater Doc Ref M107 issue 1 3 Sep 2018 2 3 Wiring Diagrams 2 3 3 External Wiring Details PZN 82 93 with two fans without connecting box 2 3 4 External Wiring Details PZN 82 93 with two f...

Страница 24: ...ting the heating function Deactivate the fan heater by acting on the room thermostat Turn the main switch to OFF Close the water check valves WARNING If there is a risk of sub zero temperatures and th...

Страница 25: ...ain all the water WARNING Always switch off and disconnect electricity supply and close the water check valve before carrying out any servicing work or replacement of failed components NOTE If a suspe...

Страница 26: ...nufacturer recommended quantities 2 5 5 Exploded Views 2 5 5 1 PZN 12 73 9 STRUCTURE Structure of Heater Types 1 14 1 Water air exchanger 6 Fixing part 2 Side panel left 7 Fixing part 3 Side panel rig...

Страница 27: ...Fan faulty Check fan motor Condenser faulty Check condenser Overload cut out tripped Check absorption POOR HEATING EFFICIENCY Heat exchanger dirty Clean exchanger Airflow obstructed Remove obstructio...

Страница 28: ...el 353 0 1452 1533 fax 353 0 1452 1764 e mail info powrmatic ie web www powrmatic ie Getting In Touch Powrmatic pursues a policy of continues improvement in both design and performance of its products...

Отзывы: