page no. 13 of 16
PQ-A Range Users, Installation & Servicing Instructions Doc Ref M308 issue 1.1 May 2019.
5. Remove the lamp holding clips by squeezing the clip
together and lifting away as shown.
6. Slide the lamp out through the extrusion feeding one
way first with the wire and then the opposite way to take
out and remove.
Take care not to scratch the reflector surface.
7. Refit the new lamp.
Take care not to mark the reflector or touch the new lamp
with the hands (see caution).
8. Replace the lamp holding clips. Make sure they are
firmly in place over the white ceramic ends of the lamp.
9. Refit the male and female connectors by fully pushing
together. Cover and refit the black sleeve.
10. Replace the front side and or middle covers in reverse
order and then refit the wire guard(s) if originally fitted.
CAUTION:
. Do not handle lamp with bare
hands.
Remove finger marks with a soft cloth and
methylated spirit or alcohol.
Finger marks will burn into quartz causing
premature lamp failure.
CAUTION:
Outer casing can reach high temperatures.