5. Remove the lamp holding clips by squeezing the clip 

together and lifting away as shown.

6. Slide the lamp out through the extrusion feeding one 

way first with the wire and then the opposite way to take 

out and remove. 

Take care not to scratch the reflector surface.

7. Refit the new lamp. 

Take care not to mark the reflector or touch the new lamp 

with the hands (see caution).

8. Replace the lamp holding clips. Make sure they are 

firmly in place over the white ceramic ends of the lamp.

9. Refit the male and female connectors by fully pushing 

together. Cover and refit the black sleeve.

10. Replace the front side and or middle covers in reverse 

order and then refit the wire guard(s) if originally fitted.

CAUTION:

. Do not handle lamp with bare 

hands.

Remove finger marks with a soft cloth and 

methylated spirit or alcohol. 

Finger marks will burn into quartz causing 

premature lamp failure.

CAUTION:

Outer casing can reach high temperatures.

Содержание PK-A1K030

Страница 1: ...w w w p o w r m a t i c c o u k PQ A User Installation Servicing Manual Issue 1 1 May 2019 Doc Ref M308 Issue 1 1 May 2019...

Страница 2: ...f Conditions of Guarantee 1 The heater must have been installed by a competent qualified installer and in accordance with the manufacturer s instructions building regulations and local regulations 2 T...

Страница 3: ...s Doc Ref M308 issue 1 1 May 2019 Title Section Contents Page User Instructions 4 Pre Installation 1 1 Introduction 4 Dimensions 6 1 2 Technical data 9 Installation 2 1 Installation 10 2 2 Maintenance...

Страница 4: ...dissipate heat in order to keep the body running cool which in turn increases life of the product and its components Installation Flexibility dedicated bracketry provide flexibility when installing on...

Страница 5: ...en recently used Remove the plug from the mains socket or disconnect pole switch during installation cleaning and or replacing the element and always ensure that the element is cool Do not handle the...

Страница 6: ...0 273 n a n a n a n a PQ A1B020 030 040 390 420 102 80 194 45 PQ A1C030 045 060 525 555 PQ A3C030 045 060 A C D B SIDE FRONT BACK MESH PATTERN NOT SHOWN A C D B E F H G MESH PATTERN NOT SHOWN SIDE FRO...

Страница 7: ...issue 1 1 May 2019 SIDE FRONT BACK FRONT BACK A B C D E F G J PQ A1J020 030 040 857 255 110 285 102 n a n a 435 PQ A3E060 090 120 630 663 102 n a 199 A C D B J MESH PATTERN NOT SHOWN A C D B E J G E M...

Страница 8: ...J G A C D B E F J SIDE FRONT BACK SIDE FRONT BACK A B C D E F G J PQ A1K030 045 060 1282 255 110 285 102 215 199 860 PQ A1K030 045 060 285 102 215 199 860 PQ A3L060 090 120 441 473 150 213 199 860 PQ...

Страница 9: ...1 17 4 2 5 0 15 1 0 857 255 110 6 0 PK A1K030 230 3 1 0 3 0 1 13 0 2 5 0 15 1 5 1282 255 110 8 0 PK A1K045 230 3 1 5 4 5 1 19 6 2 5 0 15 1 5 1282 255 110 8 0 PK A1K060 230 3 2 0 6 0 1 26 0 3 0 0 15 1...

Страница 10: ...the bracket See diagram below 2 1 1 Mounting Chain Hung Warning Switch off unplug the heater from the mains supply when mounting or adjusting the heater position The heater is suitable for installati...

Страница 11: ...1B020 The wires in the mains lead are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live Since the colours of the wires in the mains lead of this appliance m...

Страница 12: ...ger marks will burn into the lamps quartz glass causing premature failure 2 2 1 REPLACING A LAMP Warning Unplug switch off from the mains power to the heater power before any attempts are made to repl...

Страница 13: ...reflector or touch the new lamp with the hands see caution 8 Replace the lamp holding clips Make sure they are firmly in place over the white ceramic ends of the lamp 9 Refit the male and female conn...

Страница 14: ...page no 14 of 16 PQ A Range Users Installation Servicing Instructions Doc Ref M308 issue 1 1 May 2019 Notes...

Страница 15: ...page no 15 of 16 PQ A Range Users Installation Servicing Instructions Doc Ref M308 issue 1 1 May 2019 Notes...

Страница 16: ...t Dublin 24 tel 353 0 1452 1533 fax 353 0 1452 1764 e mail info powrmatic ie web www powrmatic ie Getting In Touch Powrmatic pursues a policy of continues improvement in both design and performance of...

Отзывы: